Lucent Technologies Host-Based Controller Modem AT specifications AT Commands Reference

Models: Host-Based Controller Modem AT

1 87
Download 87 pages 59.16 Kb
Page 6
Image 6
Transmit carrier always off. Normal transmit carrier switching.
n = 1

Host-Based Controller Modem

Data Addendum

AT Command Set

June 15,

1998

 

 

 

AT Commands Reference

AT commands are issued to the modem to control the modem's operation and software configuration. AT commands can only be entered while the modem is in command mode. The format for entering AT commands is:

TYPE:

ATXn

where X is the AT command and n is the specific value for that

command.

 

 

PRESS:

Enter

If n is omitted from a command that takes a parameter valu, the

value 0 I(zero)

 

 

is assumed.

Any command issued is acknowledged with a response in either text or numeric values known as result codes. Table 2 lists all the valid result codes.

In the following listing, all commands and command-values accepted by the modem are shown; any entries other than those shown cause the ERROR result code.

+++ Escape sequence

The escape sequence allows the modem to exit data mode and enter on-line command mode. While in on-line command mode, you may communicate directly to your modem using AT commands. Once you are finished, you may return to data mode using the ATO command.

A pause, the length which is set by the Escape Guard Time (S12), must be used before and after an escape sequence is issued. This pause prevents the modem from interpreting the escape sequence as data.

The value of the escape sequence character may be changed using Register S2.

A/

Repeat Last Command

This command repeats the last command string entered. Do not precede this command with an AT prefix or conclude it by pressing Enter.

A

Answer Command

This command instructs the modem to go off-hook and answer an incoming call.

Bn

Communication Standard Setting

This command determines CCITT vs. Bell standard.

B0:

Selects CCITT V.22 mode when the modem is at 1200 bits/s.

B1:

Selects Bell 212A when the modem is at 1200 bits/s (default).

B2:

Unselects V23 reverse channel (same as B3 ).

B3:

Unselects V23 reverse channel (same as B2 ).

B15:

Selects V.21 when the modem is at 300 bits/s.

B16:

Selects Bell 103J when the modem is at 300 bits/s (default).

Result Codes:

 

 

OK

 

n = 0, 1, 2, 3, 15, 16

ERROR

Otherwise

Cn

Carrier Control

 

The modem will accept the C1 command without error in order to assure backward compatibility with communications software that issues the C1 command. However, this modem does not support the C0 command. The C0 command may instruct some other modems not to send carrier (i.e., it puts them in a receive- only mode).

C0:

C1:

Result Codes:

OK

ERROR Otherwise

6

Version 1.0

Lucent Technologies Inc.

Page 6
Image 6
Lucent Technologies Host-Based Controller Modem AT specifications AT Commands Reference

Host-Based Controller Modem AT specifications

Lucent Technologies Host-Based Controller Modem AT represents a significant advancement in modem technology, particularly in the realm of telecommunications and data transmission. This modem, renowned for its efficiency and versatility, is characterized by a host-based architecture, which differentiates it from traditional modems that rely heavily on dedicated hardware.

One of the main features of the Lucent Technologies Host-Based Controller Modem AT is its ability to leverage the processing power of the host computer. By utilizing the host's CPU for data encoding and decoding tasks, the modem can reduce the need for specialized hardware components, allowing for a more cost-effective solution. This design not only facilitates lower manufacturing costs but also enhances the overall performance due to the utilization of the host's computational capabilities.

Another notable characteristic is its compliance with the AT command set, which standardizes communications between the modem and the host system. This ensures compatibility with a wide range of software applications and operating systems. The AT command set allows users to control modem functions easily, making it simpler to configure settings, initiate connections, and manage data transfer processes.

The modem also supports various communication protocols, such as V.90 and V.92, enabling high-speed data transmission over traditional telephone lines. With download speeds of up to 56 Kbps and upload speeds of up to 48 Kbps, the Lucent Technologies Host-Based Controller Modem AT is particularly suitable for Internet browsing, email, and other online activities demanding robust data throughput.

Additionally, the modem features built-in error correction and data compression protocols, such as V.42 and V.44, further enhancing the quality and speed of data transmission. These protocols help minimize the impact of line noise and ensure efficient use of bandwidth, leading to improved connection stability and data integrity.

In terms of connectivity, the Lucent Technologies Host-Based Controller Modem AT typically interfaces via a standard serial or USB port, making it compatible with most modern computers. Its compact design and ease of installation make it an appealing choice for both personal and professional use.

Overall, the Lucent Technologies Host-Based Controller Modem AT showcases significant innovation in modem technology, offering users a reliable and efficient solution for high-speed data communications. Its host-based architecture, adherence to the AT command set, and support for advanced communication protocols position it as a vital tool in the ever-evolving landscape of digital connectivity.