Configuration Steps for a Synchronous V.25bis Connection
14-4 PortMaster Configuration Guide
Configuring Global Settings
Configure the global settings to the values shown in Table14-1.
After you configure the global settings shown in Table14-1, enter the following
command to save the configuration:
Command> save all
For more information about global settings, refer to Chapter 3, “Configuring Global
Settings.”
Configuring Ethernet Interface Settings
Configure the Ethernet interface settings to the values shown in Table14-2.
After you configure the Ethernet interface as shown in Table 14-2, enter the following
command to save the configuration:
Command> save all
Table 14-1 Global Values
Setting Command
IP gateway set gateway 192.168.1.1
System name set sysname boston
Table 14-2 Ethernet Values
Setting Command
IP address set ether0 address 192.168.200.1
Netmask set ether0 netmask 255.255.255.0
IPX network set ether0 ipxnet F1
IPX frame type set ether0 ipxframe ethernet_802.2
Broadcast address set ether0 broadcast high
RIP routing set ether0 rip on