Using Synchronous Leased Lines 19-7
Configuration Steps for Leased Line Connections
After you configure the Ethernet interface as shown in Table 19-5, enter the following
command to save the configuration:
Command> save all
For more information on Ethernet settings, refer to Chapter 4, “Configuring the
Ethernet Interface.”
Configuring Synchronous WAN Port ParametersConfigure the synchronous WAN port with the values shown in Table 19-6. The IP
address for the port is left unconfigured, accepting the default IP address value of
0.0.0.0.
If you are not sure of the IP address on the other end of the connection, you can set the
IP destination to 255.255.255.255 and the PortMaster will attempt to learn the address.
Leave all other settings at their default values.
After you configure the port S1 as shown in Table19-6, enter the following commands
to reset the port and save the configuration:
Command> reset s1
Command> save all
For more information about synchronous ports, refer to Chapter 6, “Configuring a
Synchronous WAN Port.”
Table 19-6 WAN Port Values
Setting Command
Port type set s1 network hardwired
Transport protocol set s1 protocol ppp
IP destination set s1 destination 192.168.200.1
Netmask set s1 netmask 255.255.255.0
IPX network set s1 ipxnet F3
Modem control set s1 cd off
RIP routing set s1 rip on
MTU set s1 mtu 1500