Configuration Steps for an Office-to-Office Connection
15-12 PortMaster Configuration Guide
Note – Configuring the maximum ports setting to a value higher than 0 causes the
PortMaster to dial out to a continuous location, or become available for dial-out to an
on-demand location. By configuring the maximum ports setting last, you ensure that
the PortMaster will not attempt to make a connection with a location until you have
configured all the settings for that location.
After you configure the location table as shown in Table15-9, enter the following
command to save the configuration:
Command> save all
For more information about configuring location table settings, refer to Chapter 8,
“Configuring Dial-Out Connections.”
Testing the SetupYou should test the configuration before setting either of the locations for on-demand
dialing. To test the configuration, follow these steps:
1. Enter the following commands to connec t from the Paris office to the
London office:
Command> set console s1
Command> set debug 0x51
Command> dial london
2. Monitor the dial-and-connect sequence between the two locations.
3. If everything connects as expected, reset the port on the Office Route r in
the Paris office, turn off debugging, and change the loc ation type to
on-demand.
Command> reset s1
Command> set debug off
Command> set location london on_demand
✍