Lucent Technologies TM-4500 Table Of Contents, Tools And Building Supplies Normally Required

Models: TM-4500

1 20
Download 20 pages 24.44 Kb
Page 2
Image 2
TABLE OF CONTENTS

2

TABLE OF CONTENTS

 

 

Safety Rules

page

2

Tools and Building Supplies

page

2

Precautions

page

3

Introduction

page

3

Chimney/Mantel Clearances

 

 

and Height Requirements

page

3

Chimney System

page

3

Assembly Outline

page

4

Location of Fireplace

page

4

Assembly Steps

page

5

Preinstallation Notes

page

5

Fireplace Clearances

page

5

Installing the Fireplace

page

5

Fireplace Specifications

page

6

Framing Specifications

page

7

Installing the Chimney System

page

8

Ten Foot Rule Summary

page 10

Multiple Terminations

page 11

Chimney Component Calculations ...

page 11

Special Offset Instructions

page 11

Offset Calculations

page 12

Vertical Elevation Chart

page 13

Offset Elevation Chart

page 13

Installing Offsets

page 14

30° Offset through Floor/Ceiling

page 14

Optional Equipment Considerations . page 14

Combustion Air Kits

page 14

Glass Doors

page 15

Gas Line Connection

page 15

Vent Free Appliances

page 15

Cold Climate Insulation

page 15

Fireplace Finishes

page 15

Mantels and Trim

page 15

Hearth Extensions/Wall Shields

page 16

Finish Requirements

page 18

Installation Components

page 18

IMPORTANT: PLEASE READ AND UNDERSTAND THESE RULES TO FOLLOW FOR SAFETY.

1.Before starting your fireplace installation, read these installation instructions carefully to be sure you understand them completely and in entirety. Failure to follow them could cause a fireplace malfunction resulting in serious injury and/or property damage.

2.Always check your local building codes. The installation must comply with all local, regional, state and national codes and regulations.

3.This fireplace must be installed with Secu- rity Chimneys FTF10 [10" (250 mm) inside diameter] Chimney System only. These sys- tems are intended for use in any application where a traditional masonry type fireplace would apply. The chimney system must al- ways vent to the outside of the building.

4.To ensure a safe fireplace system and to prevent the build-up of soot and creosote, inspect and clean the fireplace and chimney prior to use and periodically during the heating season.

5.Use solid fuel only. DO NOT use chemical chimney cleaners or flame colorants in your fireplace.

Never burn treated construction lumber or scraps. These woods burn excessively hot and may contain chemicals used to treat insects and fungus. When burned, these chemicals can pose a significant hazard.

6.DO NOT use charcoal or coal under any circumstances.

7.NEVER use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up” a fire in this fireplace. Keep any flammable liquids at safe distance from the fireplace.

8.NEVER leave children unattended when there is a fire burning in the fireplace.

9.Always keep flue damper open when heat is present in the fireplace.

10.Before servicing, allow the fireplace to cool. Always shut off any electricity or gas to the fireplace while working on it. This will prevent any possible electrical shock or burns.

11.This fireplace is not intended to heat an entire home or be used as a primary heat source. It is designed to ensure homeowner comfort by pro- viding supplemental heat to the room.

12.Always ensure that an adequate supply of replacement combustion air from the outside of the house is accessible to the fire to support normal combustion. Fireplaces consume large volumes of air during the normal combustion process. In the event the home is tightly sealed with modern energy efficient features, the op- tional combustion air kit may not provide all the air required to support combustion.

The manufacturer is not responsible for any smoking or related problems that may result from the lack of adequate combustion air. It is the responsibility of the builder/contractor to ensure that adequate combustion air has been provided for the fireplace.

13.DO NOT use a fireplace insert or any other products not specified herein by the manufac- turer for use with this fireplace. All gas log sets must be operated with the damper clamped open, including unlisted “vent free” log sets. Listed “vent-free” log sets may be operated with the damper closed.

14."Smoke free” operation is not warranteed nor are we responsible for inadequate system draft caused by mechanical systems, general construction conditions, inadequate chimney heights, adverse wind conditions and/or un- usual environmental factors or conditions be- yond our control.

15.Never, under any circumstances, install a fireplace, chimney component or any acces- sories, that has visible or suspected physical damage as a result of handling or transporta- tion. These items should be inspected by your distributor or qualified factory representative to ensure safe condition. When in doubt, con- sult your distributor.

16.For additional safety considerations and complete operating instructions, refer to the Care and Operation Manual provided with the fireplace.

TOOLS AND BUILDING SUPPLIES NORMALLY REQUIRED

Tools should Include:

Phillips screwdriver

Hammer

Saw and/or sabersaw

Level

Measuring tape

Plumb line

Electric drill and bits

Pliers

Square

Building supplies: Framing materials Wall finishing materials

Caulking materials (noncombustible) Fireplace surround and hearth extension materials (noncombustible)

Page 2