Note: The framed depth, 28 ¹⁵⁄₁₆" (735mm) from a framed wall, must always be measured from a finished surface. If a wall covering such as drywall is to be attached to the rear wall, then the framed depth must be measured from the drywall sur- face. It is important that this dimension be exact.

If the appliance is to be elevated above floor level, a solid continuous platform must be constructed.

The header may rest on the top metal spacers, but must not be notched to fit around them.

Consult all local codes.

 

C

 

 

 

Back Wall of

 

D

Chase/Enclosure

 

Including Finishing

 

K

 

Materials if any

 

FOAK-4

 

F

 

 

 

C

 

 

A

 

 

E

Rough

 

 

Figure 15

 

Framing Face

Corner Installation

(Unfinished Shown)

Header

False Header

B2

B1

A

Fireplace Framing

Figure 12

FOAK-4 Combustion

Back Wall of Chase/Enclosure

Air Kit

Including Finishing Materials

 

 

 

if any

 

 

 

 

Framing Dimensions

A

48 ¹¹⁄₁₆"

(1237 mm)

 

 

 

B1

47 ¹⁄₄"

(1200 mm)

B2

66 ¹⁄₂"

(1689 mm)

 

 

 

C

38 ⁷⁄₈"

(987 mm)

 

 

 

D

20 ⁷⁄₁₆"

(519 mm)

 

 

 

E

96 ³⁄₄"

(2457 mm)

 

 

 

F

48 ³⁄₈"

(1229 mm)

 

 

 

G

28 ¹⁵⁄₁₆"

(735 mm)

 

 

 

J

17 ¹⁄₂"

(445 mm)

 

 

 

K

68 ³⁄₈"

(1737 mm)

 

 

 

Note: All framing dimensions calcu- lated for 5/8" nailing flange depth and 1/2" dry wall at the fireplace face. If sheathing the chase or finishing with

B

A

Ceiling Framing

Figure 16

Framing Dimensions for Ceiling

Flue Type

A

B

 

 

 

FTF10

19"

19"

Vertical

(483 mm)

(483 mm)

 

 

 

FTF10 30°

19"

29"

Offset

(483 mm)

(737 mm)

 

 

 

J

A

Rough Framing Face (Unfinished Shown)

Figure 13

G

Outside Chase

other thickness materials, calculations will need to be made.

Note: C and G dimensions include 1" clearance to combustibles.

Framing Dimensions for Roof

Pitch

C

D*

Back Wall of Chase/Enclosure

FOAK-4Including Finishing Materials

if any

G

 

 

 

A

 

 

 

 

 

 

 

 

Rough Framing Face

 

Inside Chase

(Unfinished Shown)

 

Figure 14

0/12

19"

19"

 

 

 

(483 mm)

(483 mm)

 

 

6/12

19"

22"

 

 

 

(483 mm)

(559 mm)

D

C

 

 

 

 

12/12

19"

27"

 

Roof Framing

 

(483 mm)

(686 mm)

 

 

Figure 17

 

*Perpendicular to roof ridge

 

 

 

 

 

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.