PRECAUTIONS
Note: These fireplace systems are not difficult to install. However, in the interest of safety, it is recommended that the installer be a quali- fied or certified “tradesman” familiar with com- monly accepted fireplace installation and safety techniques as well as prevailing local codes.
The most important areas of concern dealing with the installation of
IMPORTANT: WHEN INSTALLING IN CANADA, THE CHIMNEY AIR KIT MUST BE INSTALLED PER THE WARNOCK HERSEY INC. LISTING.
IMPORTANT: THE MINIMUM AIR SPACE TO COMBUSTIBLES FOR THE CHIMNEY SYSTEM IS 2" (51 MM).
INTRODUCTION
General Information
This fireplace is a conventional radiant heat fireplace with standard bar grates, optional outside combustion air kits and optional deco- rative glass doors.
Note: Illustrations shown reflect “typical” instal- lations with nominal dimensions and are for design and framing reference only. Actual instal- lations may vary due to individual design prefer- ences. However, always maintain minimum clearances to combustible materials and do not violate any specific installation requirements.
These Elite Series fireplaces have been tested and listed by Warnock Hersey Inc. (Report No.
These fireplace systems are designed for in- stallation in accordance with the National Fire Protection Standard for chimneys, fireplaces and solid fuel burning appliances; NFPA 211 and in accordance with codes such as the BOCA Basic/National Codes, the Standard Me- chanical Code, Uniform Building Codes and/or the Canadian National Code.
WARNING: FAILURE TO USE MANUFAC- TURE PROVIDED PARTS, VARIATIONS IN TECHNIQUES AND CONSTRUCTION MA- TERIALS OR PRACTICES OTHER THAN THOSE DESCRIBED IN THIS MANUAL MAY CREATE A FIRE HAZARD AND VOID THE LIMITED WARRANTY.
When complete these fireplace systems con- sist of five basic
1.The Fireplace
2.The Chimney and Termination
3.The Optional Glass Doors
4.The Optional Combustion Air Kit
5.The Chimney Collar Enclosure Kit (Canada Only)
CHIMNEY CLEARANCES AND MANTEL HEIGHT REQUIREMENTS
The fireplace may be placed on or near normal construction materials*. The combustion air kit, firestop spacer and roof flashings (not chase flashings) may be placed directly on or against normal construction materials*. The chimney requires a minimum 2" (51 mm) air space to combustibles. A combustible mantle may be installed a minimum of 12" (305 mm) above the opening of the fireplace as per NFPA 211, Sec- tion
TYPICAL INSTALLATION
Chimney
and
Termination
Optional Position | Chimney |
| Air Kit |
| (Canada Only) |
Outside Combustion Air Kit (Optional)
Figure 1
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
mm) above the opening.
The fireplace and chimney system must be enclosed when installed in or passing through a living area where combustibles or people may come in contact with it. This is important to prevent possible personal injury or fire hazard.
For questions, please call your distributor or the manufacturer. Special restrictions apply to the front and facing of the fireplace and nearby walls (See pages 16 and 17 ).
CHIMNEY SYSTEM
This fireplace is designed and code listed for use with Security Chimneys FTF10 chimney System only. Always use Security Chimneys FTF10 chimney components with this fire- place. Do not modify or alter these compo- nents as this may cause a potential serious hazard and void the Warranty.
*Construction Materials: |
|
• framing materials | • paneling |
• particle board | • flooring |
• dry wall | • etc. |
• plywood |
|
3