Lux Products 3M-22 warranty RH G 4 Wire Heat/Cool, O W2

Models: 3M-22

1 14
Download 14 pages 32.99 Kb
Page 10
Image 10

W Y RH G 4 Wire Heat/Cool

PG 17

STEP 1 - Connect the W wire to the W terminal on the

SET JUMPERS

 

 

thermostat. This connects to the heater control line.

 

 

 

 

4

 

 

 

5

STEP 2 - Connect the Y wire to the Y terminal on the

 

 

 

 

 

1 2 3

6

 

 

 

7

3M-22. This connects to the Cooler compressor.

 

8

 

 

 

 

 

STEP 3 - Connect the RH or R wire to the RH terminal on

 

 

 

 

 

 

 

 

the thermostat. This connects the Heater/Cooler Power.

 

 

 

 

 

 

 

 

STEP 4 - Connect the G wire to the G terminal on the

 

 

 

 

 

 

 

 

Thermostat. This connects to the Fan.

 

 

 

 

 

 

 

 

 

STEP 5 - Set Config jumpers per this diagram. If you

 

 

 

HVAC SYSTEM

 

 

 

 

 

 

 

 

have Electric heat set 5, if you have Gas or Oil set 7.

 

 

C W Y

 

R

Your HVAC system is now connected

OPTIONAL POWER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to the 3M-22.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Please Go To Page 9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or

G

 

 

3M-22

C B O W2 W Y Y2 RH RC G A

 

 

Terminals

 

 

 

 

 

W Y RH RC G

5 Wire Heat/Cool

 

 

PG 18

STEP 1 - Connect the W wire to the W terminal on the

SET JUMPERS

 

thermostat. This connects to the heater control line.

 

 

4

5

or

STEP 2 - Connect the Y wire to the Y terminal on the

 

3M-22. This connects to the Cooler compressor.

1 2 3

6

7

 

8

 

 

STEP 3 - Connect the RH wire to the RH terminal and the

 

 

 

 

 

RC wire to the RC terminal on the 3M-22. This connects

 

 

 

 

the Heater and Cooler Power.

 

 

 

 

 

 

STEP 4 - Connect the G wire to the G terminal on the

 

 

 

 

Thermostat. This connects to the Fan.

 

 

 

HVAC SYSTEM

 

 

 

 

 

 

STEP 5 - Set Config jumpers per this diagram. If you

 

C W Y RH RC

G

have Electric heat set 5,

if you have Gas or Oil set 7.

 

 

 

 

Your HVAC system is now connected

OPTIONAL

 

 

 

 

to the 3M-22.

 

 

C B O W2

W Y Y2 RH RC G A

Please Go To Page 9

3M-22

Terminals

Page 10
Image 10