![](/images/new-backgrounds/1041838/4183813x1.webp)
Check Unit
Follow these procedures to verify you have correctly installed the
|
| PG 11 |
| Temperature |
|
TEMP | Display | Mode |
| ||
UP button |
| Switch |
To check Fan: (If you connected the G wire - fan relay)
•Switch the FAN switch to the ON position. Verify that air is blowing from
the system. Return to AUTO position
for normal operation.
To check HEAT mode:
Set the mode switch to HEAT. Set the fan switch to AUTO.
Fan
Switch
TEMP
DOWN button
•Using the TEMP + button raise the Target Temp to 90deg. Allow the system 2 min to respond.
•Verify that heat is blowing from the system.
To check COOL mode:
•Set the mode switch to COOL.
•Press the TEMP - button to a temp 5 degrees below the room temp. Allow the system 2 minutes to respond.
•Verify that cool air is blowing from the system.
Congratulations, you have successfully installed your unit. Please proceed to the OPERATING Guide to initialize the
NOTE: If you have labeled your wires, follow the correct