SET JUMPERS
GAS Milivolt Heat
4
6
8

2 WIRE HEAT Heating GAS MILLIVOLT or 24vac

STEP 1 - Connect the R (or RH) wire to the RH terminal on

the 3M-22. This connects the Heater Power to the thermostat. STEP 2 - Connect the W wire to the W on the 3M-22.

This connects the heater control line to the 3M-22.

1 2 3

STEP 3 - Set Config jumpers per this diagram.

 

PG 15

5 7

Your Heater is now connected to the 3M-22.

Please Go To Page 9

 

C W R

OPTIONAL POWER

 

 

 

 

 

3M-22

NOTE: Wires marked with

dotted line are optional. C B O W2 W Y Y2 RH RC G A

3 Wire Heat

STEP 1 - Connect the R (or RH) wire to the RH terminal on the 3M-22. This connects to the Heater Power . STEP 2 - Connect the W wire to the W terminal on the 3M-22. This connects the heater control line to the 3M-22.

STEP 3 - Connect the G wire to the G terminal on the thermostat. This connects the Fan to the 3M-22 STEP 4 - Set Config jumpers per this diagram. If you have Electric heat set 5, if you have Gas or Oil set 7.

OPTIONAL POWER

 

 

 

PG 16

 

4

 

5 or

 

 

 

 

1 2 3

6

 

7

8

 

 

 

 

 

SET JUMPERS

 

HVAC SYSTEM

 

C

W R G

Your system is now connected to the 3M-22.

Please Go To Page 9

3M-22

C B O W2 W Y Y2 RH RC G A

Page 9