Lux Products warranty 3M-22 Features, Wire Reference

Models: 3M-22

1 14
Download 14 pages 32.99 Kb
Page 13
Image 13

3M-22 Features

PG 23

This thermostat can be used with all millivolt and 24VAC heating and cooling systems. It cannot be used with line voltage systems. This thermostat is digital and your desired heat or cool temperatures can easily be set on the large screen with the +/- buttons on the front. A minimum 4 minute off time protects heating and cooling systems from damage.

This thermostat uses a new technique called sequential staging for more comfort with

faster reaction to requested temperature changes. When using a heat pump with Aux heat, if

 

the heat pump cannot keep up and/or is

 

defective, remove jumper from position 8 and put

 

jumper on position 6 and the Aux heat will then

 

be your only source of heat. Be sure to restore it

 

to PUMP when the pump is again operational as

 

aux heat is more expensive than pump heat.

Wire Reference

PG 24

Your Wires

Filtrete Terminal

 

R or V or VR

RH and RC Single power for HEAT and COOL

 

RH or 4

RH Power for HEAT (RH not connected to RC)

RC

RC Power for COOL (RH not connected to RC)

 

W

W Heat control

 

W2

W2 2nd stage HEAT or heat pump auxiliary heat

 

?

A 3rd wire for zoned hot water heat (see zoned)

B and O

Y

Y COOL control

NOTE: If

Y2

Y2 2nd stage COOL control

there are both

G or F

G FAN control

B and O wires

C or X

C Common 24VAC power (to power thermostat)

E

Emergency heat (do not connect, tape off)

(Trane pump

products)

L

System monitor (do not connect, tape off)

DO NOT

T

Outdoor sensor (do not connect, tape off)

CONNECT B

 

 

B or

B Heat pump changeover (cool to heat, powered in heat)

to B terminal,

connect B to C

O

O Heat pump changeover (heat to cool, powered in cool)

terminal

B and O

SEE NOTE

 

Page 13