•KEEP cables away from objects such as heating and air conditioning ducts, metal construction plates, and anything else with sharp edges that can damage the cables.
Cautions: Room Station
Careful consideration should be used when determining the location of the room stations and master. Since this is a retrofit system you will not be able to control the location of the existing system. But please follow the guidelines below if you install any new locations:
•DO NOT install room stations in return air ducts.
•DO NOT install room stations in exterior walls. Insulation materials will change speaker range and efficiency. Temperature changes in the wall will reduce speaker life.
•DO NOT install room stations in saunas. They will not withstand the extreme heat and moisture.
•DO NOT install room stations underneath cabinets or over counter tops.
•DO NOT install room stations in stud cavities with other wiring or appliances.
•DO NOT install room stations within 18” of dimmers, fluorescent light fixtures, security wiring, cordless phone units, and other control wiring.
•DO NOT install room stations within 10 feet of other room stations or the
•DO NOT install room stations in stud cavities with other room stations or the
•DO NOT install room stations facing other room stations or the
•DO make sure all mounting rings are level and oriented as shown in these instructions.