dmc3-4

Next connect the wires to the dmc retrofit room station as shown in Figure 7. Match the wire colors to the corresponding screw locations on the dmc3 or dmc4 room stations. Please make sure to use only dmc3 room stations in a 3-wire installation and dmc4 room stations in a 4-wire installation. All 6-wire installations use the DMC1 room stations. Please refer to appendix A for a diagram of which NuTone and M&S systems map to the 3, 4 or 6-wire (requires dmc1 master) configurations.

Figure 7 - Room Station Wiring - 3-Wire

Refer to the charts below for the dmc3-4 wiring diagram;

NuTone Wire (IW3 or

M&S 3-Wire

dmc3-4

equivalent)

 

equivalent

 

 

 

Silver outside or blue

White

Black

tracer

 

 

 

 

 

Center conductor or gray

Black

Red

tracer

 

 

 

 

 

Other outside copper

Green

Green

wire or red tracer

 

 

 

 

 

M&S Wire

M&S or NuTone 4-conductor

dmc3-4 equivalent

 

gray jacket wire

 

 

 

 

White

Silver outside gray wire

White

 

 

 

Black

Next copper outside gray wire

Black

 

 

 

Red

Next copper outside gray wire

Red

 

 

 

Green

Outside copper outside gray wire

Green

 

 

 

www.mssystems.com 800.421.1587

Page 12

Page 12
Image 12
M&S Systems DMC3-4 installation instructions NuTone Wire IW3 or 3-Wire Dmc3-4 Equivalent