CONTROLS AND INDICATORS
1 • RCA input connectors: To connect the Pre output leads of the main unit to the amplifier input. These inputs control the final stages.
2 • Adjustment of the gain of the Input: Adjusts input sensitivity of amplifier, which can vary between 200 mV and 4V.
To adjust sensitivity, proceed as follows:
a)Set the volume control of your unit to 3/4 of its maximum output | 4V | 0,2V | |||||
|
|
|
|
|
|
| |
b)Adjust the amplifier input gain controls until the maximum possible acoustic |
|
|
|
|
|
|
|
pressure has been obtained without any distortion. |
|
|
|
|
|
|
|
3 • Stereo/Mono switch: changes the output mode of the amplifier between L(mono) |
|
| ST | ||||
Stereo and Mono. If Mono is selected, the corresponding Left (mono) input is |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
used to operate the amplifier. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
4 • Crossover switch: selects the output mode of the amplifier by activating the
a)Flat: the amplifier will reproduce the complete audio range in relation to the signal applied to the input.
Flat | Low High |
|
| 20Hz | 20kHz |
Flat Low High
20Hz 30 > 600Hz
Flat | Low High |
|
| 30 > 600Hz | 20kHz |
5 • Continuous adjustment/control of the
adjusted in continuous mode between 30 Hz and 600 Hz.
40 125
35300
30 600
7