Piping:

Use at least 1-1/2" (38mm) pipe (use 2"(51mm) pipe if possible). Increase size if a long run is needed. When using 1-1/2" pipe, connect to pump with 1-1/2" to 2" (38 to 51mm) reducing adapter.

To avoid strains on the pump, support both suction and discharge pipes inde- pendently. Place these supports near the pump.

To avoid a strain left by a gap at the last connection, start all piping at the pump and run pipe away from the pump.

To avoid airlocking, slope suction pipe slightly upward toward the pump.

NOTICE: To prevent flooding when removing pump for service, all flooded suction systems must have gate valves in suction and discharge pipes.

Fittings:

Fittings restrict flow; for best efficiency use fewest possible fittings.

Avoid fittings which could cause an air trap.

Pool fittings must conform to International Association of Plumbing and

Mechanical Officials (IAPMO) standards.

Use only non-entrapping suction fitting or double suction.

TABLE I - RECOMMENDED FUSING AND WIRING DATA

 

 

 

 

Serv. to Motor - Dist. in Ft. (M)

 

 

Motor

Branch Fuse

Max Load

Voltage/

0-100'

101-200' 201-300'

}

 

HP

Rating Amps*

Amps

Hz/Phase

(0-30)

(30-60)

(60-90)

 

 

 

 

 

 

 

 

 

1/2

15

8.5

115/50/1

2.0

2.0

2.5

 

3/4

20

11.4

115/50/1

2.5

4.0

6.0

 

1

20

14.0

115/50/1

2.5

4.0

6.0

 

1-1/2

30

16.6

115/50/1

4.0

6.0

10.0

 

 

 

 

 

 

 

 

 

1/2

15

4.25

230/50/1

2.0

2.0

2.0

 

3/4

15

5.7

230/50/1

2.0

2.0

2.0

Metric

1

15

7.0

230/50/1

2.0

2.0

2.0

Wire

1-1/2

15

8.3

230/50/1

2.0

2.0

2.0

Size

 

 

 

 

 

 

 

(MM2)

1/2

15

2.51

230/50/3

2.0

2.0

2.0

 

3/4

15

3.38

230/50/3

2.0

2.0

2.0

 

1

15

3.66

230/50/3

2.0

2.0

2.0

 

1-1/2

15

4.8

230/50/3

2.0

2.0

2.0

 

 

 

 

 

 

 

 

 

1/2

15

1.45

380/50/3

2.0

2.0

2.0

 

3/4

15

2.0

380/50/3

2.0

2.0

2.0

 

1

15

1.83

380/50/3

2.0

2.0

2.0

 

 

1-1/2

15

2.8

380/50/3

2.0

2.0

2.0

 

 

 

 

 

 

 

 

 

 

 

* Time delay fuses are recommended instead of standard fuses in any motor circuit.