ELECTRICAL

Hazardous voltage.

Can shock, burn,

or cause death.

Ground pump before

connecting to

power supply.

BONDING

LUG

GREEN

GROUND

SCREW

Figure 2 – Typical ground screw and bonding lug locations.

L2

B Voltage 115

VOLT

WHITE W/LINES BLACK TRACER

A

L1

ELECTRICAL

Ground motor before connecting to electrical power supply. Failure to

ground motor can cause severe or fatal electrical shock hazard.

Grounding/Bonding Do not ground to a gas supply line.

To avoid dangerous or fatal electrical shock, turn OFF power to motor before working on electrical connections.

Ground Fault Circuit Interrupter (GFCI) tripping indicates an electrical problem. If GFCI trips and will not reset, have a qualified electrician

inspect and repair electrical system.

Exactly match supply voltage to nameplate voltage. Incorrect voltage can cause fire or seriously damage motor and voids warranty. If in

doubt consult a licensed electrician.

Voltage

Voltage at motor must be not more than 10% above or below motor name- plate rated voltage or motor may overheat, causing overload tripping and re- duced component life. If voltage is less than 90% or more than 110% of rated voltage when motor is running at full load, consult power company.

Grounding/Bonding

Install, ground, bond and wire motor according to local or National Electrical Code requirements.

Permanently ground motor. Use green ground terminal provided under motor canopy or access plate (See Fig. 2); use size and type wire required by code. Connect motor ground terminal to electrical service ground.

Bond motor to pool structure. Use a solid copper conductor, size No. 8 AWG (8.4 sq.mm) or larger. Run wire from external bonding lug (see FIg. 2) to rein- forcing rod or mesh.

Connect a No. 8 AWG (8.4 sq.mm) solid copper bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of the swimming pool, spa, or hot tub and to all electrical equipment, metal piping or conduit within 5 feet (1.5 m) of the inside walls of swimming pool, spa, or hot tub.

Wiring

Pump must be permanently connected to circuit; be sure no other lights or ap- pliances are on the same circuit. Match wire sizes to Table I (Pg. 5).

NOTICE: To prevent dirt, rain, bugs, etc., from entering motor when not wiring with conduit, be sure to seal wire opening on end of motor.

BLACK

WHITE W/

BLACK TRACER

BLACK

WiringManual background B

L2

230

VOLT LINES

A

L1

Use Ground Fault Circuit Interrupter (GFCI) as master on-off switch; it will sense a short circuit to ground and disconnect power before it becomes dan- gerous to pool users. Test according to maker’s instructions.

In case of power outage, check GFCI for tripping (which will prevent normal water circulation). Reset if necessary.

Figure 3 – Wiring hook-up diagram Single Phase