Mad Catz 5MPRA6D-147, 5MPRA6E-148 Clogged pipe/trap/impeller, worn impeller, Electrical

Models: 5MPRA6F-156 5MPRA6D3-147 5MPRA6E3-148 5MPRA6E-148 5MPRA6C-146 5MPRA6F3-156 5MPRA6D-147

1 12
Download 12 pages 19.21 Kb
Page 11
Image 11

Clogged pipe/trap/impeller, worn impeller:

7.Make sure suction trap is not clogged; if it is, clean trap and strainer.

8.Make sure impeller is not clogged (follow steps 1 through 7 under “Removing Old Seal”, Page 9; check impeller for clogging; follow steps 7 through 11 under “Installing New Seal”, Page 10, for reassembly).

9.Impeller and diffuser may be worn. If so, order replacement parts from Repair Parts List, Page 12.

Electrical:

10.Pump may be running too slowly; check voltage at motor terminals and at meter while pump is running. If low, see wiring instructions or consult power company. Check for loose connections.

11.Pump may be too hot.

A.Check line voltage; if less than 90% or more than 110% of rated volt- age consult a licensed electrician.

B.Increase ventilation.

C.Reduce ambient temperature.

D.Tighten any loose connections.

MECHANICAL TROUBLES AND NOISE

1.If suction and discharge piping are not adequately supported, pump as- sembly will be strained. See “Installation”, Page 4.

2.Do not mount pump on a wooden platform! Securely mount on concrete platform for quietest performance.