CHAPTER 4: Troubleshooting.

Problem: Poor audio quality (continued) :

Solution:

If Daisy Chaining, audio termination must be removed in DP units. Only the last receiver requires termination. For SA units a special un-terminated version must be used between transmitters and the last receiver with a standard End-Of-Line unit installed at the end. SA units cannot be terminated/ unterminated in the field. This does not apply to SAP units.

Problem: Serial communication doesn’t work correctly.

Solution: • Are the serial devices connected properly? Are the serial parameters correct for source/destination devices?

Are the serial cables terminated correctly? If a null-modem cable is used, it must be placed at the receiver end.

For SA units a special unterminated version must be used between transmitters and the last receiver with a standard End- Of-Line unit installed at the end. SA units cannot be terminated/ unterminated in the field. This does not apply to SAP units.

SA/SAP units have a fixed baud rate of 9600 bps and use 3 wire (TX,RX,GND) signals only.

Problem:

Green shift” or “green washout” on multimedia signals.

Solution:

The standard video/serial model is designed to function with DC

 

coupled signals in which the black level is referenced to 0 volts.

 

Nearly all VGA cards function this way.

 

Some media servers, however, provide AC coupled signals and

 

can cause a green color shift in the video. This is a result of the

 

sync clamping on the red and blue channels of the video/serial

 

model.

 

For five-component (RGB/H&V) AC coupled video, the

 

MultiView CAT5 UTx Universal transmitter has been designed

 

with full DC restoration capability. This problem is easily solved

 

via a simple switch setting in the UTx Transmitter. Please refer to

 

the UTx Transmitter user manual.