2.Connect three snakes to the MDR24/96 Outputs (top connector). Connect the plug end of the snakes to the like-numbered Tape Return jacks on the 24•8 console.

MDR24/96 Settings1.Set the Sample Clock to Internal.

2.Set the Sample Rate and Bit Depth according to your preference.

Console Settings

Set the 24•8 console to the nominal +4 dBu operating level by setting the five Operating Level switches in the Sub Out and Tape Return sections to the ‘out’ position.

This example describes the hookup for the D8B console equipped for analog I/O.

 

MDR 24/96

 

 

Digital 8•Bus

AIO•8 Cards

 

AIO•8 Cards

 

 

(6) DB25 to

 

 

 

 

 

 

 

 

 

 

ANALOG I/O ANALOG I/O ANALOG I/O

DB25 Analog

ANALOG I/O ANALOG I/O ANALOG I/O

 

 

 

 

 

 

 

 

 

 

 

Snakes

 

 

 

 

OUTPUT

OUTPUT

OUTPUT

 

OUTPUT

OUTPUT

OUTPUT

Note: Some older

 

 

 

 

 

 

 

AIO•8 cards have

INPUT

INPUT

INPUT

 

INPUT

INPUT

INPUT

the Input jack la-

 

 

 

 

 

 

 

 

beled as “From

 

 

 

 

 

 

 

Tape” and the Out-

 

 

 

 

 

 

 

put jack labeled as

 

 

 

 

 

 

 

“To Tape.” Other-

 

TAPE IN/OUTS

 

 

 

TAPE IN/OUTS

 

 

 

 

 

 

 

 

wise, they operate

Cables & Hardware

identically. Sigh ...

(3)

AIO•8 cards for MDR24/96

long story.

(3)

AIO•8 cards for D8B

 

 

(6)

DB25 to DB25 analog snakes

Hookup

1.Connect three snakes between the MDR24/96 Inputs (bottom connector) and the corresponding D8B Tape Outputs (top connector).

2.Connect three snakes between the MDR24/96 Outputs (top connector) and the corresponding D8B Tape Inputs (bottom connector).

MDR24/96 Settings

1.Set the Sample Clock to Internal.

2.Set the Sample Rate and Bit Depth according to your preference. It is not necessary to set the D8B and MDR24/96 to the same Sample Rate, since with analog connections, the sample clocks on the two units are not synchronized

Console Settings

1.Set the D8B Sample Clock to 44.1 k Internal or 48 k Internal according to your preference.

Start Quick Guide

 

 

Quick Start Guide

19