MDR 24/96
Note: Determining which unit in Figure 1 provides the master clock depends on your application. For information on advanced applications, see the Applications Manual.
TDIF Hookup (DIO•8)
Cables & Hardware
(3)DIO•8 cards for MDR24/96(3)DIO•8 cards for D8B(1)Clock I/O card for D8B(3)TDIF cables(1)75 Ω BNC word clock cableHookup
1.Connect the three TDIF cables between the corresponding TDIF jacks on the MDR24/96 and D8B.
2.When TDIF is used, the D8B must have a Clock I/O card installed. To make the D8B the clock master, connect its Word Clock Out (not DIO•8 Sync out) to the MDR24/96 Word Clock In. To make the MDR24/96 the clock master, connect its Word Clock Out to the D8B Word Clock In. See Figure 1.
MDR24/96 Settings
1.Set the Tape Input format for each DIO•8 card to TDIF, and the Tape Output format to TDIF.
2.If the MDR24/96 is the clock master, set the Sample Clock to Internal; if it is a clock slave, set it to Word Clock and depress the 75 Ω termination switch on the Sync card.
3.Set the Sample Rate to 44.1 kHz or 48 kHz according to your preference.Console Settings
1.Set the Tape Input and Tape Output format for each DIO•8 card to TDIF.2.If the D8B is the clock master, set the Sample Clock to either 44.1 k Internal or 48 k Internal; if it is a clock slave, set the Sample Clock to either 44.1 kHz or 48 kHz. Set the Sample Rate to match the Sample Rate selected on the MDR24/96.
20 | MDR 24/96 |
|