From inside the fireplace, locate the knockout on the firebrick
Install 1/2 inch certified gas pipe through opening. After gas pipe installation is complete, use insulation that was removed from gas line tube to repack space around the pipe. Material should be inserted from outside of the fireplace and packed tightly to totally seal between the pipe and tube.
NOTE: Gas pipe should not come in contact with any wood structures until it has reached a point at least one (1) inch away from fireplace side.
NOTE: When installing an ANSI Z21.11.2 ventless appliance, the finishing material used for the mantel must be rated at 250°F or greater.
BTU input of a gas appliance installed in fireplace should be rated less than 100,000 BTU/Hr.
Gas pipe installation is intended for connection to a decorative gas appliance only when (1.) incorporating an automatic shutoff device and (2.) complying with the Standard for Decorative Gas Appliances for Installation in Vented Fireplaces (ANSI Z21.60) or CSA draft requirements for
Decorative gas appliance should be installed in accor- dance with the National Fuel Gas Code, ANSI Z223.1 (latest edition).
ODSHR Series
Hole in Outer |
|
|
Casing |
|
|
| 1" |
|
Gas Line | Min. | Supply |
Tubing |
| Line |
Ceramic |
| Repack |
Knockout |
| Insulation |
|
| 1/2" |
Hole in |
|
|
Outer |
|
|
Casing |
|
|
|
| Ceramic |
|
| Knockout |
|
| (both sides) |
|
| FP560SHR |
Fig. 29 Gas line access.
CAUTION: WHEN USING DECORATIVE GAS APPLIANCE, FLUE DAMPER MUST
BE SET IN FULLY OPEN POSITION. IF YOU HAVE GLASS DOORS ON THE
FIREPLACE, THEY MUST ALSO BE FULLY OPENED.
WARNING: DO NOT OPERATE AN UNVENTED GAS LOG SET IN THIS FIREPLACE WITH THE CHIMNEY REMOVED.
WARNING: WHEN INSTALLING AN UNVENTED GAS LOG SET, THE MAJESTIC MODEL AH3244BK OR AH3244PB 4" ADJUSTABLE HOOD MUST BE USED.
OUTSIDE INSTALLATION: ONLY USE THE OD30CFLN/P VENTED GAS LOG SET.
If installing an unvented gas log set, refer to statement below:
Only unvented gas log sets which have been found to comply with the Standard for Unvented Room Heaters, ANSI Z21.11.2, are to be installed in this fireplace.
20002264 | 17 |