Air Space Clearances

Combustible framing material MUST NOT penetrate AIR SPACE (shaded areas)

ODSHR Series

Flat Mantel Shelf

Stud

2"

 

 

Standoff

³⁄₄" Air Space

 

to Sides

 

Front View

Side View

 

 

Firestop

Wall

³⁄₄" Air Space

Shield

to Back

 

12" Min. to Top of Fireplace Opening

Finished Wall

Must be Sealed with

Noncombustible Material

Surround

1"

2 x 4 Stud

Finished Wall

2 x 4 Finished

Header

Ledge Bracket

Must be Sealed with Noncombus- tible Material

Finished

Wall

³⁄₄" Air Space

to Sides

Ledge Bracket

F P531

Fig. 18 Fireplace surround flush with finished wall.

Only noncombustible material may be applied as

0" Clearance to

Floor

facing to the fireplaceHearth Extension surround.

FP559SHR

Fig. 17 Minimum clearances to combustibles.

7. Finish Wall

Finish the wall with material of your choice. Do not install a combustible mantel shelf less than 12 inches above the front opening. If a combustible material is used below a flat mantel shelf, consult your local building codes for minimum clearance from top of fireplace opening to bottom of mantel shelf.

All joints (top, bottom and sides) where wall or decora- tive facing material meets fireplace surround must be completely sealed with a noncombustible material. (Figs. 18, 19, 20)

Note: No side wall protection is required for fireplaces installed at 45 degrees to two (2) side walls (corner installation).

Finished Wall

Noncombustible

Decorative

Facing

Must be Sealed with Noncombustible Material

Stud

2 x 4 Header

Ledge Bracket

Surround

Side View

FP1166

Fig. 19 Fireplace surround flush with finished wall.

20002264

13

Page 13
Image 13