CLEANING AIR CLEANER

CLEANING AIR CLEANER

A dirty air cleaner element will cause starting difficulty, power loss, engine malfunctions, and shorten engine life extremely. Always keep the air cleaner element clean.

ENGLISH

EW120R

Remove the fixing bolt of air cleaner cover.

Pull out the lower edge of the cover to remove the air cleaner cover.

Place the choke lever to the fully closed position, taking care to ensure that dust and dirt are not allowed to enter the carburetor.

Remove the element, then clean it with a solution of warm water and a mild detergent, thoroughly drying it afterward. Install it in alignment with the lines as shown in illustration.

Wipe off any oil adhering to the area around the air cleaner cover and breather with a cloth.

After cleaning, reassemble the clean- er cover (insert the tab at the top first, then insert the bottom tab) and tighten the fixing bolt.

Place so that the

Choke lever

cutout is here (top left)

 

Element

 

Breather

Air cleaner cover

Fixing bolt

Line (the slash mark)

Element (the dotted line)