NOTE :
Voltmeter always indicates the lower voltage whichever the FULL POWER SWITCH is set.
I | Switch | 1 Lower Voltage Receptacle 1 Higher Voltage Receptacle I | |
| 120v | Full rated output Is | unavailable |
| available | ||
|
|
| |
| 120/240v | half of rated output watts | Full rated output is |
| is available | available | |
|
|
TABLE 2
To utilize power from TWIST LOCK- receptacle, insert the plug into re- ceptacle and turn clockwise to lock it.
8 Be sure to ground the generator if the connected electrical equipment is grounded as instructed on page 7. If tool or appliance to be operated is grounded type (3 prong plug), be sure to use only extension cords that are also 3 wire, grounded type.
NOTE :
When the AC breaker turns off during operation, the generator has been overloaded or the appliance is defective.
Stop the generator immediately, check the appliance and/or generator for overloading or detect and have necessary repairs made by Makita factory or authorized service center.
(2)CONNECTINGTO DOMESTIC CIRCUITS (HOUSE WIRING)
All Makita generators are a neutral ungrounded type.
If a generator is to be connected to residential or commercial power lines, such as a
Failure in connection may result in death, personal injury, damage to generator, damge to appliances, damage to the building’s wiring or fire.
- 13 -