(3)DC APPLICATION

(3)DC APPLICATION

DC output capacity of generator is 12V-8.3A (1OOW).

Connect positive (red) terminal on gen- erator to position (+) terminal on battery. Connect negative (black) terminal on generator to negative (-)terminal on battery.

Both AC and DC output can be used at the same time if the total output is within rated output of the generator.

SAFETY PRECAUTIONS WHILE CHARGING

An explosive hydrogen gas is discharged through vent holes in the battery during the charging process. Do not allow spark or open flame around the generator or battery during the charging process.

Electrolyte fluid can burn eyes and clothing. Be extremely careful to avoid contact. If injured, wash the affected area immediately with large quantities of water and consult a doctor for treatment.

When charging a large capacity battery or totally discharged battery, exces- sive current may force the DC fuse to blow out. In such cases, use a battery charger to charge a large battery with AC output.

Battery defects may cause the DC fuse to blow. Check the battery before replacing the fuse.

(4)FUSE REPLACEMENT

(a)If a fuse burns out, check for the cause of trouble, and make the necessary repaires before installingthe new fuse.

(b)Be sure to use the correct fuse. An incorrect fuse may cause damage to the generator.

(c)The fuse rating for DC output is 10A.

- 16 -