Makita LF1000 dimensions Right Feet Section, Pin 8 short

Models: LF1000

1 30
Download 30 pages 55.27 Kb
Page 18
Image 18

P 18/ 30

Repair

[3] DISASSEMBLY/ASSEMBLY

[3] -9. Assembling Feet Section (cont.)

LEFT FEET SECTION

4)To Square pipe 32-510, assemble Hook and Foot. And to Square pipe 32-475, assemble Stopper hook and Foot nut. (Fig. 48)

Fig. 48

Hook

Stopper hook

 

Square pipe 32-510

Square pipe 32-475

 

Hex nut M6

Foot bolt

 

Foot

Compression spring 13

 

Foot

Foot nut

Support bracket

 

 

Foot nut

RIGHT FEET SECTION

Note: Different from the Left feet section, two 32-475 Square pipes are used for the right Feet section. 1) The same way as you did in assembling the left feet section;

Assemble Support bracket to Square pipes precisely at an angle of 90 degrees. (Fig. 45, 46) Then assemble Bracket and Pin 8 to each Square pipe. (Fig. 47, 48)

2)Assemble Stopper hook to the Square pipe 32-475 on the side of operator's position. (Fig. 49)

3)Mount Foot to each Square pipe. (Fig. 49)

Fig. 49

Pin 8 (long)

Hex nut M6

Foot

Bracket

Support bracket

Stopper hook

Pin 8 (long)

Pin 8 (short)

Foot

Page 18
Image 18
Makita LF1000 dimensions Right Feet Section, Pin 8 short