Makita LF1000 dimensions Wiring diagram UK-110V Wiring in Switch Box, Small end of Grommet

Models: LF1000

1 30
Download 30 pages 55.27 Kb
Page 30
Image 30

P 30/ 30

Wiring diagram

UK-110V

[3] Wiring in Switch Box

Do not route any lead wire in the shaded area in order not to pinch between relay and the inside wall or the boss of Switch box.

When mounting Grommet to Switch box, be sure to place;

*the big end outside of Switch box *the small end inside of Switch box.

Small end of Grommet

Big end of Grommet

Grommet

Connecting cord from Handle

Strain relief

Strain relief

Power supply cord

Do not route lead wires over Relay.

Do not place Noise suppressor on Relay.

Relay

Switch box

Noise suppressor

Terminal block

[4] Wiring at Connecting Rod

Do the same way as "All European Countries Except UK-110V". (See page 27.)

[5] Wiring Under Table

Do the same way as "All European Countries Except UK-110V". (See page 27.)