lotor will not run

Tank pressureexceeds preset

Motor will start automatically when tank pressure drops below

 

pressure switch limit

kick-in pressureof pressure switch.

 

Motor overload protection has

Let motor cool off, andoverload switch will automatically reset.

 

tripped

This may take several minutes.

 

Fuse Mown or circuit breaker

Replace blown fuse or reset circuit breaker. Do not use fuse

 

tripped

or circuit breakerwith higher rating than that specified for your

 

 

branchcircuit.

 

 

0 Check for proper fuse; ‘Fusetron” type T is acceptable.

 

 

Check for low voltage and proper extension cord size.

 

 

Disconnectother appliances from circuit. Operate compressor

 

 

on a dedicatedcircuit.

 

Check valve stuck open

Removeand dean or replace.

Pressure bleedervalve on pressure switch has not unloaded head pressure

Wrong wire gauge in cord or excessiveextension cord length

Loose electrical connections

Possibledefective capacitor

Paint spray on internal motor parts

Possibledefective motor

Bleed line by moving pressure switch lever to OFF position before restarting. If bleeder valve does not open, replace bleedervalve.

Check for proper gauge and extension cord length.

Contact authorized service center.

Have checkedat service center. Do not operate the compressor in the paint spray area.

Have checkedat service center.

16

200-2126

Page 16
Image 16
Makita MAC1000 Tank pressureexceeds preset, Tripped, Branchcircuit, Check for proper fuse ‘Fusetron type T is acceptable