P 6/ 12
Repair
[3]DISASSEMBLY/ASSEMBLY
[3]
DISASSEMBLING
(1)Remove Spool set and Safety cover as drawn in Fig. 2.
(2)Separate Motor housing (R) from Motor housing (L) as drawn in Fig. 3.
(3)Disassemble Pipe 25 complete as drawn in Fig. 6.
Fig. 6
1.Remove Lock off button B and Compression spring 12.
Lock off button B
Compression spring 12
2.Remove Pipe holder (R) by unscrewing four 4x18 Tapping screws and disconnect Lead wires (black, white) from DC motor.
Note: Be careful not to lose Rubber pin 6.
Pipe holder (R)
Pipe 25 | Rubber pin 6 |
3.Remove M6 Nut and M6x60 Hex bolt. And remove Front grip.
M6x60 Hex bolt M6 Nut
5.Remove Handle (R) from Handle (L) by unscrewing eleven 4x18 Tapping screws.
Pull out Power supply cord unit from Pipe 25 complete.
Handle (R) complete
Pipe 25 complete Pipe cap
4.While aligning the indicator (triangle) on Lock sleeve to the just center of “Unlock” and “Lock”, pull off it toward Pipe 25 side.
Pipe 25
Indicator (triangle) on Lock sleeve
Symbol of
“Lock”Symbol of
“Unlock”
Rubber sleeve 25 | Lock sleeve | 6. Remove Lock sleeve and Rubber sleeve 25. |
| ||
|
| Lock sleeve Pipe 25 complete Pipe cap |
| Power supply cord unit |
|
Handle (L) complete |
| Rubber sleeve 25 |
|
|
7.While pressing the projections on the both sides of Pipe 25 complete, pull off Pipe cap from Pipe 25 complete.
Pipe cap
Projections of | Pipe 25 |
Pipe cap | complete |