Water Pump

Maintenance

Section 4

Water Pump

Ice Thickness Probe WARNING

Disconnect the electric power to the ice machine at the electric service switch box and turn off the water supply.

1. Disconnect the water pump power cord.

POWER

CORD

WATER

LOOSEN

PUMP

SCREWS

Ice Thickness Probe

1.Compress the side of the ice thickness probe near the top hinge pin and remove it from the bracket.

DISCONNECT

WIRE LEAD

COMPRESS

HINGE PIN

TO REMOVE

ICE

THICKNESS

PROBE

PUMP

OUTLET

SV1618

Water Pump Removal

2.Disconnect the hose from the pump outlet.

3.Loosen the screws securing the pump mounting bracket to the bulkhead.

4.Lift the pump and bracket assembly off the screws.

SV1619

Ice Thickness Probe Removal

NOTE: At this point, the ice thickness probe can easily be cleaned. If complete removal is desired, continue with step 2 below.

Water Pump Removal WARNING

Disconnect the electric power to the ice machine at the electric service switch box.

2.Disconnect the wire lead from the control board inside the electrical control box.

4-6