Electrical Service

Section 2

Installation Instructions

Electrical Service

GENERAL

VOLTAGE WARNING

All wiring must conform to local, state and national codes.

VOLTAGE

The maximum allowable voltage variation is ± 10% of the rated voltage on the ice machine model/serial number nameplate at start-up (when the electrical load is highest).

QM-45 ICE MACHINE WARNING

The ice machine must be grounded in accordance with national and local electrical codes.

The 115/1/60 ice machines are factory pre-wired with a 6’ power cord, and NEMA 5-20P-plug configuration.

The 230/50/1 ice machines are factory pre-wired with a 6’ power cord only, no plug is supplied.

QM-45 ICE MACHINE

FUSE/CIRCUIT BREAKER

A separate fuse/circuit breaker must be provided for each ice machine. Circuit breakers must be H.A.C.R. rated (does not apply in Canada).

TOTAL CIRCUIT AMPACITY

The total circuit ampacity is used to help select the wire size of the electrical supply.

The wire size (or gauge) is also dependent upon location, materials used, length of run, etc., so it must be determined by a qualified electrician.

FUSE/CIRCUIT BREAKER WARNING

Never use an extension cord. If an outlet is not within reach of the ice machine’s power cord, have a proper amperage outlet wired closer to the ice machine.

 

Voltage

Air-Cooled

Ice Machine

Phase

Maximum

Total Amps

 

Cycle

Fuse/Circuit

 

 

 

Breaker

 

QM-45

115/1/60

15

5.2

 

230/1/50

15

2.6

For United Kingdom Only

As the colours of the wires in the mains lead of the appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:

The wire which is coloured green and yellow must be connected to the terminal in the

plug which is marked with the letter E or by the earth ground symbol

 

 

 

or coloured

 

green or green and yellow.

 

 

 

 

 

 

 

 

 

 

 

 

The wire coloured blue must be connected to the terminal which is marked with the letter N or coloured black.

The wire coloured brown must be connected to the terminal which is marked with the letter L or coloured red.

2-5