Installation Instructions | Section 2 |
Water Service/Drains
WATER SUPPLY
Local water conditions may require treatment of the water to inhibit scale formation, filter sediment, remove chlorine, and improve taste and clarity.
Important
If you are installing a Manitowoc
WATER INLET LINES
Follow these guidelines to install water inlet lines:
•Do not connect the ice machine to a hot water supply. Be sure all hot water restrictors installed for other equipment are working. (Check valves on sink faucets, dishwashers, etc.)
•If water pressure exceeds the maximum recommended pressure (80 psig), obtain a water pressure regulator from your Manitowoc distributor.
•Install a water
•Insulate water inlet line to prevent condensation.
DRAIN CONNECTIONS
Follow these guidelines when installing drain lines to prevent drain water from flowing back into the ice machine and storage bin:
•The ice machine comes equipped with a vinyl drain hose for use with floor drains.
•The floor drain must be large enough to accommodate drainage from all drains.
•Insulate the bin drain to prevent condensation.
•Drain lines must have a 1″ (2.5 cm) drop per 40″ (1 meter) of run, and must not create traps.
Important
The Commonwealth of Massachusetts requires that all