Manitowoc Ice QM45 Series A. Remove the Vinyl Hose, B. Remove Water Pump, Water Pump Removal

Models: QM45 Series

1 36
Download 36 pages 32.8 Kb
Page 24
Image 24
A. Remove the Vinyl Hose

Maintenance

Section 4

B. Remove Water Pump WARNING

Disconnect electric power to the ice machine at the electric switch box before proceeding.

Step 6: Remove parts for cleaning.

A. Remove the Vinyl Hose

Disconnect the water hose from the distribution tube and water pump.

B. Remove Water Pump

Disconnect the water pump power cord

DO NOT SOAK WATER

PUMP MOTOR IN

CLEANER OR

SANITIZER

SOLUTIONS

SV1694-1

Water Pump Removal

Loosen the screws securing the pump-mounting bracket to the bulkhead.

Lift the pump and bracket assembly off the mounting screws.

C. Remove the Ice Thickness Probe

Compress the side of the ice thickness probe near the top hinge pin and remove it from the bracket.

ICE

THICKNESS

PROBE

COMPRESS SIDES OF

SV1138A

ICE THICKNESS PROBE

 

Ice Thickness Probe Removal

NOTE: At this point, the ice thickness probe can easily be cleaned. If complete removal is desired follow the ice thickness probe wire to the bulkhead grommet (exit point) in the back wall. Pop the bulkhead grommet out of the back wall by inserting fingernails or a flat object between the back wall and the grommet and prying forward. Pull the bulkhead grommet and wire forward until the connector is accessible, then disconnect the wire lead from the connector.

Ice Thickness Probe Cleaning

Mix a solution of Manitowoc ice machine cleaner and water (2 ounces of cleaner to 16 ounces of water) in a container.

Soak the ice thickness probe a minimum of 10 minutes.

Clean all ice thickness probe surfaces and verify the ice thickness probe cavity is clean. Rinse thoroughly with clean water, then dry completely. Incomplete rinsing and drying of the ice thickness probe can cause premature harvest.

4-2