ACM100 User’s Manual
Electrical
Parameter | Value |
Sensed Voltage | |
Sensed Current | |
Operating Voltage | 5 to 36 Volts |
Power Consumption | 100 mA |
Load Equivalence Number (LEN) | 2 |
Reverse Battery Protection | Yes |
Load Dump Protection | Yes |
Comment
120,120/240,240,208Y,380Y configurations With supplied current transformer
DC Voltage
NMEA 2000® Interface
NMEA 2000® Spec. (1LEN = 50 mA) Indefinitely
Energy Rated per SAE J1113
Mechanical
Parameter | Value |
Size | 3.50” x 4.20” x 2.03” |
| (88.9mm x 106.7mm x 51.6mm) |
Weight | 13 oz. (368.5 g) |
Comment
Including Flanges for Mounting
Environmental
Parameter
IEC 60954 Classification
Degree of Protection
Operating Temperature
Storage Temperature
Relative Humidity
Vibration
Solar Radiation
Corrosion (Salt Mist)
Electromagnetic Emission
Electromagnetic Immunity
Safety Precautions
Value
Exposed
IP64
93%RH @40° per
4 times 7days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC
Conducted and Radiated Emission per IEC
Conducted, Radiated, Supply, and ESD per IEC
Dangerous Voltage, Electromagnetic Radio Frequency per IEC
7 Technical Support
If you require technical support for Maretron products, you can reach us in any of the following ways: