Mark Levinson N26 manual Voltage selection, PLS-226 bottom-panellabel

Models: N26

1 21
Download 21 pages 22.27 Kb
Page 12
Image 12
PLS-226 bottom-panel label

PLS-226 bottom-panel label

Voltage selection

The PLS-226 is factory-set (internally) for 100V, 120V, 200V, 220V, or 240V AC mains operation @ 50 or 60Hz. Make sure that the label on the bottom of the PLS-226 indicates the correct AC operating voltage for your location.

PLS-226 POWER SUPPLY

 

DC OUTPUTS

AC INPUT

 

WARNING: BEFORE ATTEMPTING TO

 

OPERATE THIS DEVICE, REFER TO

 

OWNER'S MANUAL FOR PROPER

 

OPERATING INSTRUCTIONS AND SAFETY

Voltage

PRECAUTIONS. HAZARDOUS VOLTAGE

AVAILABLE INSIDE; DISCONNECT AC~

indication

MAINS CABLE BEFORE REMOVING COVER.

 

 

OPERATING VOLTAGE:

 

90 – 110VAC~

210 – 240VAC~

 

105 – 125VAC~

230 – 250VAC~

 

180 – 220VAC~

~50 – 60HZ

 

 

100 – 120VAC~

 

 

MAINS

2A SLO–BLO 250VAC 3AB

 

FUSES:

200 – 240VAC~

 

 

 

1A SLO–BLO 250VAC 3AB

SERIAL NO.

DESIGNED AND MANUFACTURED IN U.S.A. BY

MADRIGAL AUDIO LABORATORIES INC.

If the voltage indicated is incorrect, see your Mark Levinson dealer.

If you wish to change the AC operating voltage of the Nº26/PLS-226, see your Mark Levinson dealer.

The Nº26/PLS-226 can be powered by a normal 15-ampere AC mains line. If other devices are also powered from the same AC line, their additional power consumption must be taken into account.