On-Screen Menu (continued)

OSD CONFIGURATION SUBMENU (continued)

OSD Tally

Use this setting to choose how tally is displayed on the screen. The available OSD Tally options depend on the Tally Source selected in the IMD Configuration submenu (see page 22).

When the Tally Source is set to Standard (contact closure), OSD Tally can be set to Off, RGY, RG, or GR:

Off

On-screen tally is disabled

RGY

Red, yellow, or green tally signals are indicated at both the bottom left and bottom right corners of the

 

 

screen. Two or three colors are shown simultaneously by subdividing each tally indicator

RG

Red tally is shown at the bottom left of the screen, and green is shown at the bottom right.

GR

Green tally is shown at the bottom left of the screen, and red is shown at the bottom right.

The following diagrams show RGY, RG, and GR OSD Tally modes:

00:00:00:00

(red)

IMD Text

(red)

RGY mode: single color activated

 

 

00:00:00:00

 

 

 

 

 

(red)

IMD Text

 

(red)

(green)

 

(green)

RGY mode: two colors activated

 

 

 

 

 

 

 

 

00:00:00:00

 

(red)

IMD Text

 

(red)

 

 

 

 

RG Mode: both colors activated

 

 

 

 

 

 

 

 

00:00:00:00

 

(red)

IMD Text

 

(red)

 

 

 

 

GR Mode: both colors activated

 

 

00:00:00:00

 

(red)

IMD Text

 

(red)

(yellow)

 

(green)

(green)

 

 

 

 

 

(yellow)

 

 

 

 

RGY mode: three colors activated

When the Tally Source is set to TSL/MEI 422, OSD Tally can be set to Off or IMD:

Off

On-screen tally is disabled

IMD

Red, yellow, and green tally is displayed according the protocol commands. Green, red, and yellow colors

 

 

are shown individually on either the bottom left or right of the screen.