Image 6
No adaptors are required to connect the 2518 DMX Controller to Martin fixture intro- duced since 1997 or any DMX-compatible fixture with 3-pin XLR connectors. The adaptors required to connect other fixtures are shown in Table 2.

No adaptors are required to connect the 2518 DMX Controller to Martin fixture intro- duced since 1997 or any DMX-compatible fixture with 3-pin XLR connectors. The adaptors required to connect other fixtures are shown in Table 2.

Standard

Pin 1

Pin 2

Pin 3

Pin 4

Pin 5

 

 

 

 

 

 

DMX

shield

cold (-)

hot (+)

-

-

 

 

 

 

 

 

Martin

shield

hot (+)

cold (-)

-

-

 

 

 

 

 

 

Table 1: Martin and DMX Pin-Outs

 

 

 

 

 

Output

 

 

 

 

 

Polarity

Martin

 

 

DMX

 

 

pin 2 (+)

 

pin 2 (-)

 

 

 

 

 

 

 

 

 

 

 

pin 3 (-)

 

pin 3 (+)

 

 

 

 

XLR

3-pin

3-pin

5-pin

 

 

 

 

Male Female

Male Female

Male

Female

Martin

pin 2 (+)

pin 3 (-)

 

1

1

1

1

1

1

3-pin

2

2

2

2

2

2

3

3

3

3

3

3

 

 

 

 

4

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

P/N 11820008

P/N 11820006

P/N 11820003

Input

 

 

 

Male

Female

Male

Female

Male

Female

 

 

 

1

1

1

1

1

1

 

 

 

 

 

 

 

pin

2

2

2

2

2

2

 

 

 

3

3

3

3

3

3

 

 

 

3-

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

DMX

pin 2 (-)

pin 3 (+)

 

P/N 11820006

P/N 11820008

P/N 11820005

 

Male

Female

Male

Female

Male

Female

 

 

 

 

 

 

 

 

1

1

1

1

1

1

 

 

 

-pin

2

2

2

2

2

2

 

 

 

3

3

3

3

3

3

 

 

 

5

 

4

 

4

4

4

 

 

 

 

 

 

 

 

 

 

 

5

 

5

5

5

 

 

 

 

P/N 11820002

P/N 11820004

 

-

Table 2: XLR Cable Requirements