Marvel Industries 61ARMBBOL manual DIMENSIONS FOR MODELS 6AROM & MPRO6ARM

Models: 61ARMBBOL

1 48
Download 48 pages 43.2 Kb
Page 14
Image 14
DIMENSIONS FOR MODELS 6AROM & MPRO6ARM

DIMENSIONS FOR MODELS 6AROM & MPRO6ARM

26716"

(67.2 cm)

2378"

(60.7 cm)

4612"

(118.1 cm)

2614"

RECOMMENDED ROUGH IN OPENING DIMENSIONS 6AROM & MPRO6ARM (66.7 cm)

231316"

(60.5 cm)

3378" to 3478"

(86.1 to 88.6 cm)

3" to 4"

7.6 to 10.2cm)

2112"

(54.6 cm)

RECOMMENDED ROUGH IN OPENING DIMENSIONS 6AROM & MPRO6ARM

** 3418" to 3518"

(86.7 to 89.2cm)

*24" (61 cm)

standard cabinet

depth

24" (61 cm)

14

Electrical Requirements: A grounded 115 volt, 15 amp dedicated circuit is required. A GFCI receptacle may be required for outdoor models.

Power outlet can be located in the back wall behind unit. Add 1" to depth for thickness of plug, or recess outlet 1" into the wall. Power outlet can also be installed in adjacent cabi- netry with a cutout for routing of power cord. Follow all local building codes when installing electrical and unit.

Product weight = 130 lbs. (59.1 kg.)

*Depth dimension may vary depending on each individual installation.

**Minimum rough in opening required is to be larger than the adjusted height of the cabinet.