Maintenance Instructions

Repairs:

This unit is not user servicable. The unit must be returned to the factory for prompt repair and calibration. This gun is equipped with a temperature cutout device intended to shut off power to the gun if set internal temperatures are exceeded. If gun doesn’t function, please refer to our warranty repair page in this booklet for additional information.

Please refer to our warranty repair page in this booklet (p8) for additional information.

Note:

Always unplug your tool before cleaning.

Heating Elements: Heating element abuse and eventual burnout can occur from one of the following conditions:

1)Improper line voltage

2)Improper attachment

3)Nozzle too close to work being heated (less than 1 inch).

Lubrication

Bearings are lubricated at tfactory and require no further lubrication.

Cleaning:

Unplug heat gun before cleaning. To clean outside of tool, use only a mild soap and damp cloth. Do not use other cleaning agents, turpentine, gasoline, lacquer or paint thinner, or other solvents that may contain chemicals which are harmful to plastics and other insulating materials. Never immerse tool in a liquid or allow a liquid to enter inside the tool. Make sure all vents and openings are free and clear of debris.

Accessories/Attachments

35016

35017

Spreader attachment

 

Heat shrink attachment

 

 

 

35289

35292

Raychem mini-gun adapter

 

Specalty connector

 

 

attachment

 

 

 

 

35294

35216

5/16” reducer

 

bench stand

Users should independently evaluate the suitability of the product for their application.

35026

Nozzle Shield

35293

9/16” reducer

35309

Attachment Kit

5 of our most popular

application tips

7

Page 7
Image 7
Master Appliance 1425-3550 FPM130-900F Maintenance Instructions, Accessories/Attachments, Repairs, Lubrication, Cleaning