5. PROGRAMMING
5.1 HOW TO CHANGE A PARAMETER VALUE MAIN MENU
1.Enter the Programming Mode by pressing the SET and DOWN key for 3s ( and start blinking).
2.Select the required parameter.
3.Press the “SET” key to display its value (now only the LED is blinking).
4.Use “UP” or “DOWN” to change its value.
Press “SET” to store the new value and move to the following parameter. To exit: Press SET + UP or wait 15 s without pressing a key.
NOTE: the set value is stored even when the procedure is exited, by waiting the
5.2 THE HIDDEN MENU (PR2)
The hidden menu includes all the parameters of the instrument.
5.2.1 HOW TO ENTER THE HIDDEN MENU (PR2)
1.Enter the Programming Mode by pressing the Set + down key for 3s ( and starts blinking).
2.When a parameter is displayed, release and
3.The Pr2 label will be displayed immediately followed from the HY parameter. NOW YOU ARE IN
THE HIDDEN MENU.
4.Select the required parameter.
5.Press the “SET” key to display its value (Now only the LED is blinking).
6.Use “UP” or “down” to change its value.
7.Press “SET” to store the new value and move to the following parameter.
To exit: Press SET + up or wait 15s without pressing a key.
NOTE: the set value is stored even when the procedure is exited by waiting the
5.2.2 HOW TO MOVE A PARAMETER FROM THE HIDDEN MENU TO THE FIRST LEVEL AND VICEVERSA
Each parameter present in the HIDDEN MENU can be removed or put into “THE FIRST LEVEL” (user level) by pressing “SET + down”.
In HIDDEN MENU when a parameter is present in First Level the decimal point LED is on.
5.3HOW TO LOCK THE KEYBOARD
1.Keep pressed for more than 3s the UP and DOWN keys.
2.The “POF” message will be displayed and the keyboard will be locked. At this point it will be possible only to see the Set Point or the MAX o MIN Temp stored
3.If a key is pressed more than 3s the “POF” message will be displayed.
5.4TO UNLOCK THE KEYBOARD
Keep pressed together for more than 3s the UP and DOWN keys.
6. LIGHT MANAGEMENT
6.1 TIMED REGULATION: I1L = Y
With i1L = y the light remains on at least for the LHt parameter.
The LHt timer is
With LHt=0 the light remains on until the light button is pushed again.
The light is switched on every time one of the following conditions happens:
•the door is open (i1F = dor)
•the presence sensor is activated (i2F = LHt)
•the light button is pushed
The light is switched off when all the following conditions happen:
•the LHt timer is exhausted
•the door is closed (i1F = dor)
•the presence sensor is