TROUBLESHOOTING GUIDE

TROUBLESHOOTING GUIDE

SYMPTOM

CAUSE

POSSIBLE SOLUTION

 

 

 

Burner will not light

Not enough gas flow from propane

Open propane tank all the way

 

tank

 

BURNER LIGHTING INSTRUCTIONS

1.Check the regulator to be certain it is in the OFF position before connecting to the gas cylinder. Perform soapy water test before each use.

2.Open tank cylinder valve.

LOW BATTERY GAS FLOW

3. To start timer operation, push POWER button; both lights will blink once.

Flujo el gas

Basse Batterie

Batteria Baja

Ecoulement de gaz

 

Low gas level in propane tank, or

Check gas level in propane tank

 

tank is empty

 

 

 

 

 

Blockage in burner

Clean and check burner for spiders,

 

 

insect nests, or other debris

 

 

 

 

Faulty burner

Contact Masterbuilt at

 

 

1.800.489.1581

 

 

 

Hissing or gurgling sounds coming

Water in burner

Check burner for moisture, make

through gas train from tank to

 

sure burner is dry

burner

 

 

Damaged hose

Perform soapy water test to check

 

 

 

for cracks - See page 14

4.Press START button; green light will remain on, allowing 15 minutes of gas flow.

5.Turn regulator on.

6.Place a lit match to the burner from under the wind shield as shown below.

7.Slowly turn regulator control knob clockwise until the burner lights.

•Timer will run 15 minutes before shutting gas flow off.

START

COMIENZO

POWER

ENERGIA

PUISSANCE

 

Gas leak

Check all connections in gas train for

 

 

possible leaks - See page 14

 

 

 

Timer does not work

Batteries are dead

Replace batteries - See page 11

 

 

 

 

Did not press power or start button

Follow timer instructions - See page

 

 

10

 

 

 

 

Faulty timer

Contact Masterbuilt at

 

 

1.800.489.1581

 

 

 

Timer stopped before time was up

Batteries are dead

Replace batteries - See page 11

 

 

 

Excessively yellow and irregular

Blockage in burner

Clean and check burner for spiders,

flame

 

insect nests, and other debris.

 

 

 

 

Air damper not adjusted correctly

Adjust air shutter to the burner until

 

 

the burner flame is as blue as

 

 

possible - See page 9

 

 

 

Flame has gone out

Low gas level in propane tank, or

Check gas level in propane tank

 

tank is empty

 

 

 

 

 

Too much wind

Check wind direction and set cooker

 

 

away from windy areas - See page 3

 

 

 

 

Blockage in burner

Clean and check burner for spiders,

 

 

insect nests, and other debris

 

 

 

 

Water in burner

Check burner for moisture, make

 

 

sure burner is dry

 

 

 

 

Faulty burner

Contact Masterbuilt at

 

 

1.800.489.1581

•At 5 minutes remaining, gas flow light will blink slowly. At 2 minutes remaining gas flow light will blink quickly.

•If burner does not light within 5 seconds, turn regulator control valve OFF, then turn gas cylinder valve OFF. Wait 5 minutes for fumes to diminish, turn timer knob clockwise until its stops before relighting.

•If the flame is blown out wait 5 minutes for fumes to diminish before resetting timer and relighting.

•After the burner is lit, open the regulator valve until the flame increases. Use the air shutter on the burner to adjust the flame until it turns blue. Reduce flame.

•Fill Pot with water or oil. DO NOT fill pot more than 1/3 the pots full capacity. This will help avoid dangerous boil-overs. Note: DO NOT place your empty pot over the open flame. This will damage pot.

•Bring water or oil to the desired temperature by adjusting regulator control valve. Oil should never exceed 400°F (204°C). Oil will ignite at 550°F (287°C) to 700°F (371°C).

•Always use a thermometer when frying.

•After each use, first turn the regulator control valve OFF, then turn the gas cylinder OFF. Always allow fryer stand and pot with water or oil to cool completely before touching, moving, or storing.