5.1.39 AT+CNMI – New Message

This command allows you to determine how the modem shall notify the user when a SMS message is received from the network operator.

Enter

Response

AT+CNMI=<mode>,<mt>,<b

Set message indication mode.

m>,<ds><bfr>

 

AT+CNMI?

Display current values

 

+CNMI<mode>,<mt>,<bm>,<ds>,<bfr>

AT+CNMI=?

Display list of supported values.

 

+CNMI<mode>,<mt>,<bm>,<ds>,<bfr>

Where <mode>

Buffer unsolicited result code modem. If buffer is full, the oldest

 

indications may be discarded and replaced with the new

 

received indication.

 

Discard indication and reject new received messages unsolicited

 

result codes when serial port is in use. Otherwise forward them

 

directly to the user.

 

Buffer unsolicited result codes in the modem when the serial link

 

is in use and deliver them when the serial link is unused.

 

Forward unsolicited result codes directly to the user. Serial link

 

specific in-band used to embed result codes as data when the

 

modem is in on-line mode.

<mt>

Disable SMS-deliver indication.

 

If SMS-deliver is stored in modem, indication of memory location

 

routed to the user using +CMTI<mem>,<index> indication that

 

new message has been received.

 

SMS deliveries are routed directly to the user.

 

Class 3 SMS deliveries are routed directly to the user.

<bm>

No CBM, Cell Broadcast Message, is routed to the user.

 

If CBM, Cell Broadcast Message, is stored in modem, indication

 

of memory location is routed to the user using the

 

+CBMI<mem>,<index>.

 

SMS status disabled.

 

SMS status report enabled.

<bfr>

The results codes buffered in the modem are sent to the user

 

when mode 1…3 is entered.

 

The result code is cleared when mode 1…3 is entered.

 

Notes:

 

Result codes:

 

OK

 

ERROR

 

Message service failure result codes.

 

+CMTI<mem>,<index> indication that new messages has been

 

received.

 

+CBMI indication of new cell broadcast

ME 820047

Issue 1.0

Page 24

03/00

Page 32
Image 32
Maxon Telecom MM-6864, MM-6854 manual 39 AT+CNMI New Message, At+Cnmi=?

MM-6854, MM-6864 specifications

Maxon Telecom is renowned for its innovative communication solutions, and two of its standout products are the MM-6864 and MM-6854 models. Both devices are designed to cater to the needs of modern enterprises, offering robust features and cutting-edge technology to enhance communication effectiveness.

The Maxon Telecom MM-6864 is a feature-rich communication device that emphasizes versatility and connectivity. One of its main features is its ability to support multiple communication protocols, making it compatible with a wide range of network systems. This flexibility is essential for businesses that require seamless integration with existing infrastructures. The MM-6864 also boasts advanced encryption technology, ensuring secure communications to protect sensitive information.

Another characteristic that sets the MM-6864 apart is its expansive coverage capabilities. The device utilizes the latest in antenna technology, which not only extends its range but also improves signal strength in challenging environments. This makes it an ideal choice for enterprises operating in remote locations or large facilities where maintaining a reliable connection is paramount.

On the other hand, the Maxon Telecom MM-6854 is tailored more towards compactness and user-friendliness without compromising on features. One of its significant characteristics is its lightweight design, making it easy to carry and suitable for on-the-go professionals. The MM-6854 also offers impressive battery life, allowing users to stay connected throughout their busy day without the constant need for recharging.

Both devices incorporate advanced digital signal processing (DSP) technology, ensuring clear audio quality during communications. This is crucial in fast-paced business environments where understanding every detail is vital. Additionally, they come equipped with customizable user interfaces, enabling users to tailor settings according to their specific needs, whether they are on a conference call or conducting day-to-day operations.

In conclusion, the Maxon Telecom MM-6864 and MM-6854 models stand out in the telecommunications landscape due to their combination of advanced features, reliable connectivity, and user-centric designs. Whether a business requires the extensive capabilities of the MM-6864 or the portability of the MM-6854, Maxon Telecom delivers devices that meet diverse communication needs while ensuring security and efficiency.