MANTEL CLEARANCESInches (mm)

 

 

 

 

 

12 (305) MANTEL

 

 

 

 

 

 

10 (254) MANTEL

 

 

 

 

 

 

8 (203) MANTEL

 

14

 

 

 

 

6 (152) MANTEL

 

12

 

 

 

 

 

(356)

 

 

 

4 (102) MANTEL

 

(305)

10

 

 

TOP OF

 

 

 

 

 

 

 

(254)

 

 

 

 

 

8

 

2 (51) MANTEL

APPLIANCE

 

 

 

6

 

 

 

 

(203)

 

 

 

 

 

 

(152)

4

 

 

 

 

 

 

(102)

 

 

 

 

NOTE - Hood shown as positioned

 

 

 

 

in louvered front model. The hood

 

 

 

 

position in the flush faced front model

 

 

 

 

is lower than shown.

 

*Note - The side walls of mantels may protrude beyond the front face of the fireplace a maximum of 5 inches (127mm) at 0 inch clearance to the sides of the fireplace.

Figure 37

INSTALLATION ACCESSORIES

The following accessory items are available for use in the installation of this appliance.

Outside Combustion Air Kits

Cat. No.

Model No.

Description

 

 

 

81L87

FOAK-4

Combustion Air Kit (w/duct)

 

 

 

81L88

FOAK-4LD

Combustion Air Kit (w/o duct)

 

 

 

FINISHING REQUIREMENTSWall Details

Complete finished interior wall. To install the appliance facing flush with the finished wall, position framework to accommodate the thickness of the finished wall (see Figure 38).

A hearth extension is not required with this appliance. If a hearth extension is used, do not block the control compartment access panel. Any hearth extension used is for appearance only and does not have to conform to standard hearth extension installation requirements.

Note: Combustible wall finish materials and/or surround materials must not be allowed to encroach the area defined by the appliance top spacers. Never allow combustible materials to be positioned in front of or overlapping the appliance front face and top spacers. See

Figure 38.

Non-combustible materials, such as surrounds and other appliance trim, may be installed on the appliance front face with these exceptions: they must not cover any portion of the glass or louvers.

Vertical installation clearances to combustible mantels vary according to the depth of the mantel. (refer to Figure 37). Mantels constructed of non-combustible materials may be installed at any height above the appliance opening; however, do not allow anything to hang below the hood.

COLD CLIMATE INSULATION

If you live in a cold climate, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests, if floor is above ground level.

Combustible Wall

This Area Must Remain

Framing

Clear of Combustible

Combustible

Materials

 

Finished Wall

1" Min

Materials

 

(25 mm)

Combustible

 

Wall Framing

 

Spacer

 

3 in. Min.

 

(76 mm)

 

NonCombustible

Top of Appliance

Louvers

Finished Wall

Top of Door Frame

Materials

 

Hood must be installed as shown.

Louver Face Models

Figure 38

Outside Air Kits Models FOAK-4 and FOAK- 4LD

Outside Air kits are available with duct (FOAK-4) and without duct (FOAK-4LD) for use if outside combustion air is required or desired. If model FOAK-4LD is used it must be used in conjunction with locally purchased, non-combustible Class 1 or Class 0 flexible duct.

White Wall Switch Kit

Cat.No.

Model No.

Description

 

 

 

85L87

FWSK

OFF/ON Wall Switch Kit

 

 

 

OFF/ON Wall Switch Kit

The OFF/ON wall switch kit may be used to control the operation of the fireplace burner. Install the OFF/ON wall switch in a convenient location near the fireplace.

18

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.