| 12 (305) MANTEL |
|
|
|
|
|
| 10 (254) MANTEL |
|
|
|
|
|
| 8 (203) MANTEL |
|
14 |
|
|
|
| 6 (152) MANTEL |
|
12 |
|
|
|
|
| |
(356) |
|
|
| 4 (102) MANTEL |
| |
(305) | 10 |
|
| TOP OF | ||
|
|
|
|
| ||
|
| (254) |
|
|
| |
|
| 8 |
| 2 (51) MANTEL | APPLIANCE | |
|
|
| 6 |
| ||
|
|
| (203) |
|
| |
|
|
|
| (152) | 4 |
|
|
|
|
|
| (102) |
|
|
|
| NOTE - Hood shown as positioned |
| ||
|
|
| in louvered front model. The hood |
| ||
|
|
| position in the flush faced front model |
| ||
|
|
| is lower than shown. |
|
*Note - The side walls of mantels may protrude beyond the front face of the fireplace a maximum of 5 inches (127mm) at 0 inch clearance to the sides of the fireplace.
Figure 37
The following accessory items are available for use in the installation of this appliance.
Outside Combustion Air Kits
Cat. No. | Model No. | Description |
|
|
|
81L87 | Combustion Air Kit (w/duct) | |
|
|
|
81L88 | Combustion Air Kit (w/o duct) | |
|
|
|
Complete finished interior wall. To install the appliance facing flush with the finished wall, position framework to accommodate the thickness of the finished wall (see Figure 38).
A hearth extension is not required with this appliance. If a hearth extension is used, do not block the control compartment access panel. Any hearth extension used is for appearance only and does not have to conform to standard hearth extension installation requirements.
Note: Combustible wall finish materials and/or surround materials must not be allowed to encroach the area defined by the appliance top spacers. Never allow combustible materials to be positioned in front of or overlapping the appliance front face and top spacers. See
Figure 38.
Vertical installation clearances to combustible mantels vary according to the depth of the mantel. (refer to Figure 37). Mantels constructed of
If you live in a cold climate, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests, if floor is above ground level.
Combustible Wall | This Area Must Remain | |
Framing | Clear of Combustible | |
Combustible | Materials | |
| ||
Finished Wall | 1" Min | |
Materials | ||
| (25 mm) | |
Combustible |
| |
Wall Framing |
| |
Spacer |
| |
3 in. Min. |
| |
(76 mm) |
| |
NonCombustible | Top of Appliance | |
Louvers | ||
Finished Wall | ||
Top of Door Frame | ||
Materials | ||
|
Hood must be installed as shown.
Louver Face Models
Figure 38
Outside Air kits are available with duct
White Wall Switch Kit
Cat.No. | Model No. | Description |
|
|
|
85L87 | FWSK | OFF/ON Wall Switch Kit |
|
|
|
The OFF/ON wall switch kit may be used to control the operation of the fireplace burner. Install the OFF/ON wall switch in a convenient location near the fireplace.
18 | NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. |