B. Electronic Wiring (See Figure 17 or 18)

Note: The electronic appliance must be connected to the main power supply.

A junction box is located at the rear of the control compartment on either side of the cabinet. The junction box on the right side contains a factory installed and wired outlet box (duplex receptacle). Also, an optional field-provided junction box with receptacle may be installed at the front of the control compartment on either side of the cabinet. See Figure 16. It will be held in place by a conduit fitting and locknut (field-provided).

See Figure 4 on Page 5 for

Optional Electrical Inlet

Knockout Location.

* Field-Provided

Junction Box and

Duplex Receptacle

*Narrow (2 1/8 Inch Wide) J-Box Required

Optional J-Box/Outlet Box

Step 6. WIRING - OPTIONAL FORCED AIR BLOWER KITFBK-100, FBK-200 and FBK250 Kits(See Figure 17 for FBK-100, FBK-200 and Figure 18 for FBK-250 wiring) -

An electrical outlet box (receptacle) is factory -provided for the installation of the FBK-100, FBK-200 and FBK-250forced air blower kits. (An optional field-provided outletbox/J-Box may also be used. Electrical power must be connected to either of these receptacles in order to operate these blowers. Install the blower kits according to the installation instructions provided with the kits.

Electronic Wiring Diagram (Honeywell) Showing the Blower Wiring for the Optional FBK-100 and FBK-200 Kits

1.If any of the original wire as supplied must be replaced,

1.it must be replaced with Type AWM 105°C – 18 GA. wire.

2.120V, 60Hz – Less than 3 amps.

 

**Leave the ON/OFF switch, which is integral

**ON/OFF Switch (Integral

with the gas valve, in the ON position.

 

with Gas Valve)

*OPTIONAL

 

Note: The tab connecting the receptacles of the outlet box must be broken in FBK-100 and FBK-200 blower kit applications.

IMPORTANT: Ground supply wire must be connected to the green wire attached to the outlet receptacle's green ground screw. See Figures17 or 18. Failure to do so will result in a potential safety hazard. The appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, the National Electrical Code, ANSI/NFPA 70-(latest edition). (In Canada, the current CSA C22-1 Canadian Electrical Code).

Electronic Wiring Diagram (Honeywell) Showing the Blower Wiring for the Optional FBK-250 Kits

1.If any of the original wire as supplied must be replaced,

1.it must be replaced with Type AWM 105°C – 18 GA. wire.

2.120V, 60Hz – Less than 3 amps.

 

 

 

*Leave the ON/OFF switch, which is integral

*ON/OFF Switch (Integral

 

with the gas valve, in the ON position.

 

 

with Gas Valve)

 

Outlet Box Green

 

 

 

 

 

Gas Valve

 

Ground Screw

 

 

Figure 16

(Left Side Shown)

 

Gas Valve

ACCESSORY

 

PILOT

SWITCH

 

ASSEMBLY

 

BK

IGNITER

BK

120

 

 

 

PILOT

G

 

 

 

ASSEMBLY

120

 

IGNITER

BK

BK

 

 

VAC.

 

W

 

 

 

1. Route a 3-wire 120Vac 60Hz 1ph power supply to the appliance junction box.

2. If the factory-provided outlet/junction box at the right rear of the fireplace is being used, remove the outlet box from the junction box by removing two screws.

3. Connect the power supply wires (includ- ing the ground supply wire) as shown in Figure 17 or 18. (If the field-providedJ-box/outlet box is being used, all of the outlet box wiring must be field-provided).

4. Locate and install a low voltage (24V) wall-mounted switch or thermostat (both field-provided) in the desired location.

5. Connect the low voltage wire, located in the lower control compartment, to the wall- mounted switch or thermostat.

Note:The supplied 15 feet of 2 conductor wire has one end of each conductor connected to the gas valve circuit and the other end of each conductor placed inside the control compartment.

6. Insert the control circuit plug into the un- switched receptacle of the outlet box.

7. After wiring is complete, mount the outlet box to the J-Box.

Note: The gas valve-mounted ON/OFF switch is shown in Figure 17 or 18. It is integral with the gas valve and should be set to the ON position.

 

 

Outlet Box

 

W

VAC.

 

 

 

G

R

 

Green Ground

 

 

BL

Screw

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPT

 

G

Red

 

 

 

BLOWER

 

 

 

 

 

pigtail

 

 

 

 

Break Off

 

 

 

 

 

 

Black

 

 

 

 

Tab

 

 

 

 

 

 

 

pigtail

 

 

 

 

 

 

 

White Wire

 

 

 

 

 

to Opposite

 

 

W

Junction Box

 

Side

 

 

 

 

Transf.

 

 

 

 

B

 

 

 

 

 

G

 

120 V.

 

 

Hot side of Outlet

 

 

 

 

 

 

 

BL

 

24 V

 

 

 

 

 

 

 

W

 

 

 

R

 

 

 

 

 

 

 

BK

 

 

 

 

 

 

 

 

BK

 

BK

 

 

OPTIONAL WALL SWITCH

 

LIMIT SWITCH

 

OR OPTIONAL THERMOSTAT OR

 

 

 

 

OPTIONAL REMOTE RECEIVER

*Blower speed control switch is provided in FBK200 blower kit.

Factory Wired

Field Wired

Schematic Representation Only

Figure 17

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

ROptional FBK-250

BLModule

OPT

 

 

BLOWER

 

White Wire

 

 

 

 

To Opposite

 

 

Side

 

 

Junction Box

W

 

Transf.

B

 

 

G

120 V.

Hot side of Outlet

 

 

BL

 

24 V

 

 

 

 

R

W

 

BK

 

 

BK

 

BK

OPTIONAL ON/OFF SWITCH,

 

LIMIT SWITCH

WALL SWITCH, THERMOSTAT

 

 

OR REMOTE CONTROL RECEIVER

 

 

Factory Wired

 

Field Wired

Schematic Representation Only

Figure 18

9