TABLE OF CONTENTS

 

 

Packaging .........................................

Page

2

Introduction ......................................

Page

2

General Information ..........................

Page

2

Location ............................................

Page

4

Appliance Clearances ........................

Page

4

Fireplace Specifications.....................

Page

5

Gas Vent Rule ...................................

Page

5

Framing Specifications......................

Page

6

Typical Installation Sequence ............

Page

6

Installing The Fireplace .....................

Page

7

Vent System Installation ...................

Page

8

Field Wiring.......................................

Page

8

Connecting Gas Line .........................

Page 10

Outside Air Kit Installation.................

Page

10

Installing Logs .................................

Page

11

Appliance Operation..........................

Page

16

Millivolt Appliance Checkout .............

Page

16

Electronic Appliance Checkout ..........

Page

16

Installing Glass Door.........................

Page

16

Burner Adjustments ..........................

Page 17

Spillage Test......................................

Page

17

Manual Limit Switch .........................

Page 17

Hood Installation...............................

Page

17

Finishing Requirements ....................

Page

18

Cold Climate Insulation .....................

Page

18

Installation Accessories ....................

Page

18

Gas Conversion Kits ..................

Page 19

This installation manual will help you obtain a safe, efficient, dependable installation for your appliance and vent system.

Please read and understand these instructions before beginning your installation.

PACKAGING LIST

The assembled vented gas fireplace is packaged with:

1 - One log set located in firebox area.

2 - One envelope containing the literature package which consists of the homeowner's manual, installation instructions, log set supplement and warranty; envelope is located in the control area.

3 - One hood located behind the top panel.

4 - One bag of decorative volcanic stone located in the control area.

5 - One bag of glowing embers (rockwool) located in the control area.

2

INTRODUCTION

These vented gas fireplaces are designed to operate on either natrural or propane gas. They must be installed with approved type-B, double wall vent pipe systems routed to the outside atmosphere.

The Millivolt appliances have a millivolt gas control valve with piezo ignition system provides safe, efficient operation. If any optional accessories which require electrical power are being installed, the electrical power must be provided at the time of appliance installation.

The Electronic appliances have an electronic intermittent pilot ignition system provides safe, efficient operation. External electrical power is required to operate these units.

These appliances comply with National Safety Standards and are tested and listed by OMNI- Test Laboratories, Inc. (Report No. 116-F-36-5) to ANSI Z21.50 (in Canada, CSA 2.22), and CAN/CGA-2.17-M91 in both USA and Canada, as vented gas fireplaces.

Misc. Codes / Standards -

The Installation must conform to local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition, or the Natural Gas and Propane Installation Code, CSA B149.1 - latest edition.

The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 - latest edition, or the Canadian Electrical Code, CSA C22.1 - latest edition.

DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THE APPLIANCE OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION MAY VOID THE WARRANTY, CERTIFICATION AND LISTINGS OF THIS UNIT.

WARNING

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistanceoradditionalinformation consult a qualified installer, service agency or the gas supplier.

NEW YORK CITY, NY AND MASSA- CHUSETTS REQUIREMENTS

These appliances are approved for installation in the following USA locations listed in the following:

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Massachusetts -

Installation of these fireplaces are approved for installation in the US state of Massachusetts if the following additional requirements are met -

Installation and repair must be done by a plumber or gas fitter licensed in the Com- monwealth of Massachusetts.

The flexible gas line connector used shall not exceed 36 inches (92 centimeters) in length.

The individual manual shut-off must be a T-handle type valve.

New York City, New York -

Installation of these fireplaces are approved for installation in New York City in the US state of New York (approval no. MEA 417-05-E), if the following additional requirements are met -

An outside air kit (FOAK-4 or FOAK-4LD) must be installed. See Figure 1a and Page 18 for ordering information.

GENERAL INFORMATION

Note: Installation and repair should be performed by a qualified service person. The appliance should be inspected annually by a qualified professional service technician. More frequent inspections and cleanings may be required due to excessive lint from carpeting, bedding material, etc.

It is imperative that the control compartment, burners and circulating air passageways of the appliance be kept clean.

S'assurer que le brùleur et le compartiment des commandes sont propres. Voir les instructions d'installation et d'utilisation qui accompagnent l'apareil.

Provide adequate clearances around air openings and adequate accessibility clearance for service and proper operation. Never obstruct the front openings of the appliance.

VerticalVenting

Shown with Outside Air Kit installed (model FOAK-4 or FOAK-4LD)

Figure 1a