B: Beep Menu – ~/MENU B B |
|
T his m enu c ontrols th e beep func tions of a Mu ltiMA X. |
|
Pres s th e corres pond ing letter to set th e desired |
|
func tion of the |
|
A: Beep on All – ~/MENU B B A |
|
Mu ltiMA X will beep on all triggering, c onfirm ation | Beep Menu |
errors , and zero coun ts as indic ated below as well as | |
on any key pressed. |
|
B: B eep on T rigger – ~/MENU B B B |
|
Unit w ill beep w hen triggered b y TEST button , PO RT 1, a R adio T rigger, or th e Hot Shoe in the following manner:
Bee p C haracteris tic | Indicates |
Single Sh ort Beep | Indic ates P roper C onfirm ation |
Single Long Beep | Indic ates T rigger E rror |
Single Very Short Beep | W hen an y Key is p ress ed |
C: B eep on Z ero / Err or – ~/MENU B B C |
|
T he M ultiM AX unit will not b eep on norm al trigg ering . T he M ultiM AX will beep only when the cou nter reac hes zero and on confirm ation errors in the followin g m anner:
Bee p C haracteris tic | Indicates |
Single Long Beep | Indicates Trigger Confirmation error or remote MultiMAX |
| (unit set for RECEIVE m ode) has reached zero count |
Dou ble Long Beep | Indicates MultiMAX has reached zero count |
Single Sh ort Beep | An y Key is p ress ed excep t TEST |
LA M ultiMA X (s et for R EC EIV E m ode) set to Beep on Zero / Error or set to Beep on All will indicate a c onfirm ation error if the u nit is als o set to c ount d own an d the c ounter reach es zero. S ee the Counter section, Page 30, for more information.
D:Beep D isab le – ~/MENU B B
Turns off all beep functions. Unit will not beep.
29