To equalize two cameras and one flash at 1/125 with one MultiMAX, follow these steps:

1.

Set the MultiMAX to REC EIVE mode

2.

Measure lag times of cameras as described and record the fastest lag for each

3.

Determ ine whic h c amera is fas ter and whic h is slow er overall

4.

Determine the delay time

 

a.

If the s low cam era is m ore con sis tent us e this f ormu la:

 

 

i.

Slow er C amera’s Fas test Lag T ime M IN US F aster C amera’s

 

 

 

Fas test Lag T ime M INUS 0.0025 {calculated safety margin}

 

b.

If the f ast c amera is more c ons istent u se this formu la:

i.Slow er C amera’s Fas test Lag T ime M IN US F aster C amera’s Fas test Lag T ime PLUS 0.0025 {calculated safety margin}

5.

Press ~/MENU A A B then enter the calculated delay time from Step 4

6.

Attach the slower camera’s motor drive to PORT 1

7.

Attach the faster camera’s motor drive to PORT 2

8.

Attach the flash to the more consistent (sm allest lag time variance) cam era

9.

T rigger th e RE CE IVE unit either f rom th e TEST key or from a T RAN SM IT unit

T wo U nit Eq ualization

T wo U nit Eq ualization is b asic ally the sam e as above, bu t allows the tw o cam eras to be m ore rem ote. T he d iff eren ce in c alculations compen sates for radio trig ger delay.

1.

Set one MultiMAX to REC EIVE mode, and one to TR ANS MIT mode

2.

Us ing the R EC EIV E u nit, measure the lag tim es of each c amera as describ ed

 

above and record the fastest lag for each

3.

Determ ine whic h c amera is fas ter and whic h is slow er overall

4.

Determine the delay time

 

1.

If the s low cam era is m ore con sis tent us e this f ormu la:

 

 

1.

Slow er C amera’s Fas test Lag T ime M IN US F aster C amera’s

 

 

 

Fas test Lag T ime M INUS 0.0030 {calculated safety margin}

 

2.

If the f ast c amera is more c ons istent u se this formu la:

 

 

1.

Slow er C amera’s Fas test Lag T ime M IN US F aster C amera’s

 

 

 

Fas test Lag T ime PLUS 0.0020 {calculated safety margin}

5.

On the RECEIVE unit press ~/MENU A A A. Enter the time from Step 4

6.

Attac h the s lower camera’s motor d rive to PO RT 2 on th e TRA NS MIT unit. D o

 

not leave the MultiMAX (set for TRAN SMIT m ode) in the hot shoe or have the

 

PC termin al attached to PO RT 1 as this m ay caus e a looping or lock-up situation

7.

Attach the f aster camera’s motor dr ive to either P O RT on the REC EIVE unit

8.

Attach the flash to the more consistent (sm allest lag time variance) cam era

9.

Trigger the system from the TRANS MIT unit’s TEST key