Troubleshooting
W hen in dou bt !
Many issues can be resolved by powering the unit off and then back on again or by resetting to factory default settings. Before proceeding to any other troubleshooting procedure follow these steps:
1. | Set power to OFF |
2. | W ait 10 second s or until display completely blanks |
3. | Set p ower to R EC EIV E or T RA NS MIT |
Reset to Default Factory Settings | |
1. | Set power switch to OFF |
2. | Press and hold C key |
3. | Continue to hold C and s et the power sw itch to either R EC EIV E or T RA NS MIT |
4. | Releas e C key when CLEA R/R ES ET mess age appears |
Default factory settings are as follows: |
|
| |
Ch annel | 17 | Display Contrast | Medium |
T rans mitter | A B C D L all | Delay Time | 0.01 00 s ec |
Zones | enabled |
|
|
Receiver Zone | A | Equalize | 0.15 00 s ec |
|
| Calculated Time |
|
Relay Mode | OFF | Interval Time | 100 sec |
Operating mode | NORMAL | Multipop Time | 1.00 sec |
Contact Time | 0.12 sec | Counter Mode | OFF |
Beep Mode | All | Cou nter Load | 36 |
Fast Mode | OFF |
|
|
NThe following indic ators m ay operate erratically durin g res et, but w ill return to norm al operation wh en res et com pletes: B attery Level, Frequ enc y Lock, Beep Mod e, and Channel.
LThe CLEA R/RES ET m essage also displays the software version installed in the unit. T o view just th e software vers ion withou t losing setting s ref er to the Software Version Display section, Page 40, for more information.
53