ALARM
1. ALARM ENABLE
To set the ALARM ENABLE. It will be triggered by event occurrence when the setting is ON.
2. ALARM DURATION
Set the reaction time which was determined by how long the alarm mode responded to a buzzer. Default setting is 10 sec. Options are 10 SEC, 15 SEC, 20 SEC, 30 SEC, 1 MIN, 2 MIN, 3 MIN, 5 MIN, 10 MIN, 15 MIN, 30 MIN, ALWAYS, AUTO.
3. REC IPS
Select the images per second of recording during an ALARM. The options are as following: NTSC- 30、 15、 8、 4、 2、 1
PAL- 25、 12、 6、 3、 2、 1
4. QUALITY
There are four quality settings during an ALARM : BASE, BEST, HIGH, NORM.
(MENU)
TIMER CAMERA RECORD ALARM DWELL PIP MOTION DISPLAY REMOTE USER SYSTEM EVENT
5. RECORD MODE
There are three record mode settings :
DWELL
(ALARM)
ALARM ENABLE | YES |
ALARM DURATION | 15 MIN |
RECORD IPS | 30 |
QUALITY | NORMAL |
RECORD MODE |
1. NORM
To set up the DWELL time period that each channel auto sequentially shows on call monitor. The level is from 1 to 15 SEC or OFF.
2. ALARM
To set up the DWELL time period when alarm input is triggered. The level is from 1 to 15 SEC or OFF.
(DWELL)
NORM ALARM
CAM1 01 01
CAM2 01 01
CAM3 01 01
CAM4 01 01
(MENU)
TIMER CAMERA RECORD ALARM DWELL PIP MOTION DISPLAY REMOTE USER SYSTEM EVENT
PIP
1. FULL SCREEN
To set up the full screen background picture display.
2. PIP SCREEN
To set up the picture with a 1/9 size screen “insert”.
3. POSITION
There are six position settings : D/L, D/M, D/R, U/L, U/M, U/R.
(PIP)
FULL SCREEN | CAM 1 |
PIP SCREEN | CAM 2 |
POSITION | D/R |
(MENU)
TIMER CAMERA RECORD ALARM DWELL
PIP MOTION DISPLAY REMOTE USER SYSTEM EVENT
14