PRODUCTSPECIFICATIONS
Power Requirements
MODE | 12V ± 10% | 5V ± 5% | POWER | |
|
|
|
|
|
2100 mA | 275 mA |
|
| |
|
|
|
| |
Seek (avg) | 740 mA | 420 mA | 11.0 W | |
|
|
|
| |
Read/Write (avg) | 295 mA | 440 mA | 5.7 W | |
|
|
|
|
|
Idle (avg) | 230 mA | 380 mA | 4.7 | W |
|
|
|
|
|
Standby (avg) | 20 mA | 220 mA | 1.3 | W |
|
|
|
|
|
Sleep (avg) | 20 mA | 155 mA | 0.9 | W |
|
|
|
|
|
Power Mode Definitions
Spin-up
The drive is spinning up following initial application of power and has not yet reached full speed.
Seek
A random access operation by the disk drive.
Read/Write
Data is being read from or written to the drive.
Idle
The drive is spinning, the actuator is parked and powered off and all other circuitry is powered on. The drive is capable of responding to read commands within 40 ms.
Standby
The spin motor is not spinning. The drive will leave this mode upon receipt of a command that requires disk access. The
Sleep
This is the lowest power state – with the interface set to inactive. A software or hardware reset is required to return the drive to the Standby state.
EPA Energy Star Compliance
Maxtor Corporation supports the goals of the U.S. Environmental Protection Agency’s Energy Star program to reduce the electrical power consumption of computer equipment.
Environmental Limits
PARAMETER | OPERATING |
|
|
|
|
|
|
Temperature | 5° C to 55° C |
| low temperature |
|
|
| high temperature (71° C) per |
|
|
| climatic category; |
Thermal Gradient |
| 25° C per hour (maximum) | |
|
|
|
|
Relative Humidity |
| 5% to 95% | |
|
|
|
|
Wet Bulb |
|
| 27° C (maximum) |
|
|
|
|
Altitude |
| ||
|
|
|
|
Acoustic Noise (Idle mode) | 3.1 bel average sound power |
|
|
| (per ISO 7779, 10 microphone) |
|
|
3 – 3